Operator's Manual
Table Of Contents
- About This Manual
- Product Description, Features and Indications for Use
- Safety Information, Warnings and Cautions
- Chapter 1: Technology Overview
- Signal Extraction Technology® (SET®)
- rainbow Pulse CO-Oximetry Technology
- Pulse CO-Oximetry vs. Drawn Whole Blood Measurements
- General Description for Total Hemoglobin (SpHb)
- General Description for Total Arterial Oxygen Content (CaO2)
- General Description for SpOC
- General Description for Carboxyhemoglobin (SpCO)
- General Description for Methemoglobin (SpMet)
- General Description for Respiration Rate (RRp)
- General Description for Oxygen Reserve Index (ORi)
- SpCO, SpMet, and SpHb Measurements During Patient Motion
- rainbow Acoustic Monitoring™ (RAM™)
- Chapter 2: Description
- Chapter 3: Setting Up
- Chapter 4: Operation
- Using the Touchscreen and Home Button
- About the Main Screen
- About the System Status Light
- Accessing Main Menu Options
- rainbow Parameter Settings
- Parameter Settings
- Temperature Settings
- Noninvasive Blood Pressure (NIBP) Settings
- NomoLine Capnography Settings
- Sounds
- Device Settings
- About
- Trends
- Call
- Rad-97 Screenshot Capture
- Patient Admit/Discharge
- EMR Push
- Chapter 5: Profiles
- Chapter 6: Temperature
- Chapter 7: Noninvasive Blood Pressure (NIBP)
- Chapter 8: NomoLine Capnography
- Chapter 9: Video Conferencing
- Chapter 10: Admit to and Discharge from Patient SafetyNet
- Chapter 11: Electronic Medical Records (EMR) Push
- Chapter 12: Third-Party Devices
- Chapter 13: Alarms and Messages
- Chapter 14: Troubleshooting
- Chapter 15: Specifications
- Pulse CO-Oximetry Specifications
- Temperature Specifications
- Noninvasive Blood Pressure (NIBP) Specifications
- NomoLine Capnography Specifications
- Electrical
- Environmental
- Physical Characteristics
- Alarms
- Display Indicators
- Compliance
- Connectors
- Wireless Specifications
- Guidance and Manufacturer's Declaration-Electromagnetic Emissions
- Guidance and Manufacturer's Declaration-Electromagnetic Immunity
- Recommended Separation Distances
- Symbols
- Citations
- Chapter 16: Service and Maintenance
- Appendix: Concepts of Alarm Response Delay
- Index
Rad-97 Chapter 15: Specifications
www.masimo.com 187 Masimo
Effects from Water Vapor Partial Pressure on Gas Readings
When the breathing gas flows through the sampling line, the gas temperature will adapt to
the ambient temperature before reaching the gas analyzer. The measurement of all gases will
always show the actual partial pressure at the current humidity level in the gas sample. As
the NOMO section removes all condensed water, no water will reach the NomoLine
Capnography gas analyzer. However at an ambient temperature of 37 °C and a breathing gas
with a relative humidity of 95% the gas reading will typically be 6% lower than corresponding
partial pressure after removal of all water.
Electrical
AC Power Requirements
AC Power requirements 100 to 240 VAC, 47 to 63 Hz
Power consumption 60 VA
Fuses
UL, Metric (5x20mm), rated min. 250 VAC, 1 Amp, Time Delay,
min.1500A breaking capacity
Battery
Type Lithium ion
Capacity Approx. 4 hours [11]
Charging Time 6 hours [12]
Environmental
Environmental Conditions
Operating Temperature 0°C to 40°C (32°F to 104°F)
Storage/Transport Temperature -20°C to 60°C (-4°F to 140°F) [13]
Operating Humidity