Troubleshooting guide

APPENDIX F
DRIVE CAM INSERT LOOSE (CONTAINER CLOSED)
1 To remove the dial, cut off the knob close to the dial.
2. Make a continuous vertical cut around the knob and parallel to the dial.
3. Pull the knob off with vise grips.
4. Loosen hub set screws.
5. Remove hub and dial.
6. Remove the dial ring cover.
7. Remove the black plastic inner tube retainer.
8. Caution, the flex cables are exposed to damage from here on out.
9. Replace the hub that was removed and tighten the set screws onto the spindle and execute
combination.
10. Bias the spindle using a Bic pen or a similar tool as illustrated in Fig. 5 to create enough
friction between the cam and its insert to turn the generator and power up the X-07.
11. When container is opened, replace the cam.