Troubleshooting guide
APPENDIX B
REMOVING THE X-07 DIAL (CONTAINER OPEN)
1 Remove the drawer head cover plate.
2. Remove the back drill plate and filler plate.
3. Remove the X-07 back cover assembly.
Remove the two screws on perimeter of the cover assembly. One is on the end of cover
assembly and the other is on the side. Both screws are Phillips head screws and require a
#2 Phillips screw driver.
Lift the cover assembly out perpendicular to the lock assembly. Care must be exercised
here because the female connector on the system card mates up with an 11 pin male con-
nector on the case assembly. If removed at a sever enough angle, the 11 pin male connec-
tors may have one or more pins slightly bent. Even a slightly bent pin may prevent, or inhibit,
the reinstallation of the cover assembly.
4. With cover assembly removed, remove the straight slot/hex screw (depending on type of
screw) from center of cam. (See Figs. 7 & 8) This screw attaches the drive cam to the
spindle.
5. With screw removed, remove the drive cam from the spindle.
6. Remove the dial assembly and spindle by pulling on the dial knob from the front.