Troubleshooting guide

lever spring is not completely compressed the relocker lever will only be partially lifted. This
may result in the slide assembly tab being blocked as the dial is turned to the right. The following
is a list of the possible causes for the relocker failure.
1 . Back cover assembly mounting screws are loose.
If the back cover assembly mounting screws are loose, you may be able to use a deadblow
hammer to open the lock. First you must get a dial block right by dialing the correct combi-
nation. When you get “OP”, hold light turning pressure clockwise (right) while hitting the
container just outside the dial ring assembly. You must vibrate the back cover assembly
enough to overcome the mechanical relock spring.
2. Thermal fuse has melted or is indented.
3. Relocker lever is not lifted enough to allow slide to move.
MAGNETIC RELOCKER
The magnetic relocker is a pin device mounted on an angle into the X-07 bolt. If a strong
magnetic field is placed near the device it will fire the pin into the case assembly guide track in
which the bolt travels back and forth. Once the pin has fired, all movement of the bolt toward the
open position will be blocked.
NOTE: Vibrating the container handle and/or using a deadblow hammer strik-
ing at the 5 o’clock position outside the dial ring may reset the magnetic
relock pin if your lock is mounted in the VD (Vertical Down) or LH (Left
Hand) position.
DIAL BLOCKED LEFT AND RIGHT ON COMBINATION CHANGE
The X-07 dial can only be turned ¼ revolution in either direction after opening the container and
inserting the change key. Dial block left and right on initial dialing of the combination is usually
caused by the container locking rods blocking the X-07 bolt.
First, a bit of information about the containers and the locking bars. The bars are two equal
lengths of hardened steel that extend out of the container drawer head and into the side walls of
the container. When extended, the locking bars prevent any movement of the drawer head.
When retracted, these bars are clear of the container walls and allow the container drawer to be
pulled out of the container.
When the locking bars are extended, the container locking mechanism is designed to leave a
space between the locking bars that is sufficient for the X-07 bolt to extend into, yet small
enough to restrict the travel of the locking bars when the container is closed and the X-07 bolt is
extended between them.
Remember, when changing the combination, the container drawer must be out and in the locked
position. That is, the container locking handle must be in the up position.