Troubleshooting guide

After executing the combination and with “OP” displayed, the X-07 dial is restricted when
turned to the right. When the dial is turned back to the left and “OP” goes out, the dial is free
turning.
First, a bit of information about the containers and the locking bars. The bars are two equal
lengths of hardened steel that extend out of the container drawer head and into the side walls of
the container. When extended, the locking bars prevent any movement of the drawer head.
When retracted, these bars are clear of the container walls and allow the container drawer to be
pulled out of the container.
When the locking bars are extended, the container locking mechanism is designed to leave a
space between the locking bars that is sufficient for the X-07 bolt to extend into, yet small
enough to restrict the travel of the locking bars when the container is closed and the X-07 bolt is
extended between them.
1. X-07 bolt may be binding or jamming as it is retracted from the gap between locking bars.
2. After executing the combination and with “OP” displayed, turn the dial slowly to the right
while feeling and listening for the slide mechanism to engage.
3. If you feel the mechanism has engaged, do the following:
a. Slightly force the dial to the right adding force as you attempt to open. Hold pressure on
the container handle toward the closing direction or “jiggle” the handle.
b. Open drawer and remove dust cover and check the gap between the container locking
bars for sufficient space to accommodate the X-07 bolt.
c. Inspect bolt on the X-07 for gouges and scratches from scraping on bars.
d. Make adjustment (usually by grinding or filing locking bars) and replace parts as re-
quired.
DIAL RESTRICTED WHEN CLOSED/TURNS FREELY WHEN CON-
TAINER OPEN
First, a bit of information about the containers and the locking bars. The bars are two equal
lengths of hardened steel that extend out of the container drawer head and into the side walls of
the container. When extended, the locking bars prevent any movement of the drawer head.
When retracted, these bars are clear of the container walls and allow the container drawer to be
pulled out of the container.
When the locking bars are extended, the container locking mechanism is designed to leave a
space between the ‘ locking bars that is sufficient for the X-07 bolt to extend into, yet be small
enough to restrict the travel of the locking bars when the container is closed and the X-07 bolt is
extended between them.
Note: If the lock has just been opened the X-07 dial will be blocked to the right
with