Troubleshooting guide

2. Follow instructions in Appendix I
ELECTRONIC CARD FAILURE
1 . There is not a lot that can be done at this point. If time permits, let the X-07 sit idle for 72
hours to allow the stored power in the super capacitor to discharge to a minimum level, then
try to power up with quick half turns of the dial.
2. A sharp blow on the container (at the 5 o’clock position) with a dead blow hammer MAY
make a loose connection and allow the X-07 lock to power up.
3. If unsuccessful, see forced entry. (Appendix H)
DIALING RESTRICTED
POSSIBLE CAUSES
1. Improper clearance between dial assembly and dial ring cover assembly.
2. Dial ring assembly installed off center.
3. Bent spindle.
4. Generator gears binding.
5. Motor gear installed 180 degrees out of sync.
CLEARANCE BETWEEN DIAL ASSEMBLY AND DIAL RING COVER ASSEMBLY
1 . Gage was not used and/or spindle has been cut too short.
2. Requires replacement of the dial assembly and/or spindle.
DIAL RING ASSEMBLY INSTALLED OFF CENTER
Requires realignment of the dial ring.
See Figure 11.
1. Execute combination to open container.
2. Pull out the drawer, release the interlock, and extend the locking bars to the locked position.
3. Turn the X-07 dial to extend the bolt into the locked position.
4. Follow the instructions for Appendix B.
5. Remove the dial ring cover from the dial ring assembly by removing the two Phillips screws.