Troubleshooting guide
1 . Security violation.
2. Hub assembly set screws loose.
3. Drive cam assembly insert loose.
4. Faulty LCD or card failure.
SECURITY VIOLATION
1 . Exceeded maximum error count without getting “OP”.
a. Ten (10) errors in succession will cause the X-07 lock to blank out the LCD. The LCD will
remain off until the lock has totally powered off. Power off occurs 90 seconds after dialing
has stopped.
b. If you do not stop dialing for 90 seconds the electronic will remain powered up and the LCD
will stay blank.
c. Confirm your combination and dialing techniques.
HUB ASSEMBLY SET SCREWS LOOSE OR GROOVED ON SPINDLE -
Dial turns independently of spindle; no generator feedback (rasping) is detected.
1 . Gain access by following directions in Appendix C.
2. Separate hub assembly from dial; replace hub assembly onto spindle, tighten set screws, turn
hub to power up X-07 lock.
3. Execute combination and open container.
4. Replace dial assembly with new one.
DRIVE CAM ASSEMBLY INSERT LOOSE
1 Check for generator feedback (rasping) as you turn the dial and spindle with your finger tips.
If you CAN hear the feedback, proceed to faulty LCD (Appendix E), otherwise continue by
following instruction in Appendix F.
2. If you are successful in powering up the lock and can execute the combination, open the
container.
3. Replace the drive cam and dial assemblies following the instructions in Appendix B.
FAULTY LCD, BAD CONNECTION, OR FLEX CABLES SEVERED
1. Follow instructions in Appendix E.