Operating instructions

10
The display will flash the new combination two times and then display the symbol
PO (Pull Out Change Key).
Note: If the correct combination is not displayed, you may pull out the
change key and the lock will allow you to reset the combination. You must
pull out the change key while the display is still flashing. When EC appears,
insert the change key again and dial the desired combination.
11. Pull out the Change Key. The Change Key symbol will disappear and dL will
appear.
12. Dial left until CC (Confirm Combination) is displayed.
13. Dial right to dial the new combinations again for confirmation.
Note: In Dual Combination Mode you may dial either combination first to
confirm. In Super/Sub Mode you must dial the Supervisory combination first.
and the Subordinate Combination second as you did when first entering the
combinations.
When OP (OPen right) appears on the display, the new combinations have been
set.
IF YOU LOCK THE CHANGE KEY IN THE SAFE
If the door of your container is shut and the X-08 accidentally locked with the Change
Key still inserted in the back of the lock, you can recover with the following procedure.
1. Dial left (CCW) until lock is “powered”.
2. Dial right to dial the current combination. SL will be displayed.
3. Dial right to select ANY valid mode - 1,2 or 3. (Do Not select 0.) dL will appear.
4. Dial left continously without pausing until E1 or C1 is displayed without the
Change Key appearing in the upper right hand corner.
Note: Multiple symbols will be displayed during this dialing process and
the LCD will go totally blank at one point. Finally, E1 and C1 will appear
with the Change Key still showing in the upper right hand corner. It is
imperative that you continue to dial until the Change Key disappears, leaving
either E1 or C1 on the display, depending on the previous operating mode.
5. Dial right to dial the existing combination. OP will appear.
6. Dial right to retract the bolt. You may now restart the procedure to Set the Operating
Mode and Change Combination(s).
Note: You cannot use the serial number in place of the combination for this
procedure. The combination must be known.