OPERATING INSTRUCTIONS X-08 /CEX-08 TM TM Type 1F HIGH SECURITY ELECTRONIC LOCK Please read all instructions carefully before putting your X-08/CEX-08 into operation.
Table of Contents INTRODUCTION ................................................................................... 3 LOCK ON BACK COVER ........................................................................... 3 DIALING THE X-08/CEX-08 .................................................................. 4 DIALING METHODS .................................................................................. 4 TO POWER THE LOCK .............................................................................
INTRODUCTION The X-08/CEX-08 uses sophisticated computer security and makes dialing much easier than that of traditional combination locks. The microprocessor in the lock recognizes a number as part of a combination when you stop dialing on that number and wait for the number to be registered. This enters the number into the computer’s memory. Your X-08/CEX-08 lock has been shipped preset in the Single Combination Mode with the factory combination of 50-25-50.
DIALING THE X-08/CEX-08 DIALING METHODS The user should dial with complete full wrist turns. Stopping to regrip produces pauses in dialing activity. This helps the X-08 distinguish between human and robotic dialers. The X-08 may mistake a human for a robot if the user dials more than 1.3 revolutions in the ClockWise (CW) direction with no pauses in dialing activity. Important: The X-08 has protective software that detects robotic dialing.
Note: When dialing to the right after the E1, E2, or E3 prompts, the first numbers to appear on the LCD will alternately be 00 or 50. DO NOT stop on these numbers the first time they appear if they are part of your three number combination. Continue to dial to the right until the number appears for the second time. If at any time the dial remains stationary for more than 10 seconds, the computer will reset (LCD will go blank) requiring the operator to redial the entire combination.
OPENING THE X-08/CEX-08 (FACTORY COMBINATION) If you have not read the section on “Dialing the X-08”, it is important that you do so before proceeding. CW=ClockWise; CCW=CounterClockWise 1. Dial left (CCW) until lock is “powered”. Stop. E1 will be displayed. 2. Dial right (CW) until the first number of the factory combination, 50, appears on the LCD. Note: When dialing to the right after the E1, E2, or E3 prompts, the first numbers to appear on the LCD will alternately be 00 or 50.
X-08/CEX-08 LOCK SETUP Setting up the X-08 lock for operation involves both the operating mode and the combination(s). Before you can set a new combination, you must select and set a mode of operation. The X-08 has three modes of operation: Single Combination Mode: The X-08 will open when one three-number combination is successfully dialed. Dual Combination Mode: Two separate combinations are required to open the X-08.
Note: Hold your thumb on the change key retractor while inserting the Change Key to ensure that the pins enter the lock and are not being pushed back into the Change Key. 3. Release the container locking bolts. (Different containers will have different release mechanisms.) 4. Dial left (CCW) until the Change Key appears in the upper right hand corner of the display along with E1 on the main part of the display. Note: The lock will never open when the Change Key symbol is displayed. 5.
The new combination will be displayed twice, two digits at a time, followed by PO. Note: If the correct combination is not displayed, you may pull out the change key and the lock will allow you to reset the combination. You must pull out the change key while the display is still flashing. When EC appears, insert the change key again and dial the desired combination. 9. Pull out the Change Key. The Change Key symbol will disappear and dL will appear. 10. Dial left. CC (Confirm Combination) will appear. 11.
The display will flash the new combination two times and then display the symbol PO (Pull Out Change Key). Note: If the correct combination is not displayed, you may pull out the change key and the lock will allow you to reset the combination. You must pull out the change key while the display is still flashing. When EC appears, insert the change key again and dial the desired combination. 11. Pull out the Change Key. The Change Key symbol will disappear and dL will appear. 12.
USING THE X-08/CEX-08 If you have not read the section on “Dialing the X-08”, it is important that you do so before proceeding. SINGLE COMBINATION MODE In this mode the X-08 functions much like a standard combination lock. It will open any time the three-number combination is correctly dialed. 1. Dial left until lock is “powered”. 2. Dial right to dial the combination. EXAMPLE: Combination = 30-60-90 E1 will be displayed. Dial right to first number, 30. Stop. E2 will appear.
SUPERVISORY/SUBORDINATE MODE In this mode, two combinations must be correctly dialed to open the lock. However, it is different from Dual Mode because the Supervisory Combination must only be dialed once to UnLock (UL) the lock. Once the Supervisory Combination has been entered, the Subordinate Combination can be used to open the lock at any time during this “unlocked” state.
To Lock Up (LU) Supervisory Operator: 1. Dial left until lock is”powered”. 2. Dial right to dial the Supervisory Combination as if dialing the combination to open the lock. EXAMPLE: Combination = 25-50-75 E1 will be displayed. Dial right to first number, 25. Stop. E2 will appear. Dial right to second number, 50. Stop. E3 will appear. Dial right to third number, 75. Stop. LU (Locked Up) will be displayed indicating the lock cannot be opened.
AUDIT FEATURES OF THE LOCK The X-08 lock tracks the number of successful openings for the lifetime of the lock. It also tracks the number of consecutive unsuccessful attempts and will alert you upon lock power up if there have been 3 or more consecutive unsuccessful attempts to open the lock. The lock bolt must be extended and the lock allowed to power down prior to obtaining an audit count. TO CHECK THE NUMBER OF SUCCESSFUL OPENINGS Start this process when the lock is powered down (i.e.
SURREPTITIOUS ATTEMPT SA indicates that a Surreptitious Entry Attempt condition exists. An X-08 lock will register a Surreptitious Entry Attempt condition when fifteen unsuccessful attempts to open the lock are made. The condition must be reset using the Reset Combination before the lock will open and operate normally.
CHANGE RESET COMBINATION This procedure is similar to changing a combination when operating in Single Mode. Note: The Factory default for the Reset Combination = 50-25-50. 1. 2. 2. 3. 4. Dial left (CCW) until lock is “powered”. Dial right to dial the combination(s) to open the lock. Insert the Change Key into the back of the lock. Release the container locking bolts. Dial continuously to the left (CCW) until the number of successful openings is displayed.
Once the lock has been successfully opened, the Reset Combination can be changed using the serial number. To Change Reset Combination using Serial Number: 1. Insert the Change Key into the back of the lock. 2. Release the container locking bolts. 3. Dial left until lock is “powered”. 4. Dial right to dial the current combination(s) for the lock. ES (Enter Serial Number) will appear. 5. Dial right to dial the six-digit serial number of the lock just as you would dial the six-digit combination.
CEX-08 FEATURES The CEX-08 lock is a variation of the X-08 lock that includes a Covert Entry detection feature. The Covert Entry function is used to indicate that the normal operation of the CEX-08 has been compromised. The following section describes the unique features and operations of the CEX-08. You should already be familiar with the standard operation of the X-08 as described in the preceding sections before proceeding.
RESET CE CONDITION If CE is displayed, then you will need to reset the Covert Entry condition using the following steps. The lock must be powered down before beginning the reset process. The same Reset Combination that is used for resetting the SA condition is used for resetting the CE condition. Note: The factory default for the Reset Combination is 50-25-50. 1. Dial continuously to the left (CCW) until the number of successful openings is displayed. 2. Dial right to 99. E1 will appear. 3.
GUIDE TO SYMBOLS Blank Display Means the lock has been reset or is powered down. OP Open Right Lightning Bolt Incorrect Combination Dialed. (When this symbol appears in the upper left corner of the display, simply redial combination.) UL Unlocked LU Lock Up Key Change Key Symbol (The Change Key has been inserted and the lock is in Change Combination Mode.
CC Confirm Combination or Combination(s) CE (CEX-08 only) A Covert Entry condition exists CA (CEX-08 only) Covert entry detection is Active dL dial Left ES Enter Serial Number Lightning Bolt and Key Displayed during CE combination change SA A Surreptitious Entry Attempt Exists SC (CEX-08 only) Both a Surreptitious Entry Attempt and a Covert Entry condition exists C1 Enter first Combination C2 Enter second Combination. Note: Some displays will only be seen on CEX-08 locks.
Document Number 500.018 Rev. D 06/99 Converted to Acrobat 08/00 Notice: The information in this manual is subject to change without notice and does not represent a commitment on the part of Mas-Hamilton Group (MHG). MHG shall not be liable for technical errors or omissions contained herein; nor for incidental or consequential damages resulting from the furnishing, performance or use of this material.