- CAN modification pinouts
- Can work with any Mini-RX beacon or Beacon HW v4.9 with 25kHz ultrasonic
sensors (radio bands must match)
- Most of all designed to work together with Outdoor versions of Mini-RX beacons
and heavy outdoor Industrial-TX and Industrial-RX beacons (radio bands must
match)
- Up to 30m with Beacon Mini-RX
- Optional external Converter-220V-12V-IP67 (except version from April 2022, it
supports only +5V power supply)
- Wide transmitting diagram
Determine carefully the version of your Industrial beacons: it may
be built before September 2019 and after September 2019. If it is
beacon from the late batch, you must use Industrial Super-beacon
SW. if you have beacons from the early batch, use Industrial-RX or
Industrial-TX SW. Stickers’ differences: Later batch – Ind-RX-S or
Ind-TX-S. Early batch Beacon Ind-RX or Beacon Ind-TX.
Version 2 and 3 of Industrial-TX-Metal (from June 2022) supports ONLY +5V
power supply. Don’t use +12V power supply converter for this version, it will burn
the beacon!
This version doesn’t have UART RX, but now is possible to use Interface connector
as a power supply.