O WNERS G UIDE OWNER'S GUIDE MARVEL UNDERCOUNTER REFRIGERATION M ARVEL UNDERCOUNTER REFRIGERATION MO OD D EE LL ## M MLLN RP E1 21 25 4 FOR M T H E O R I G I N A L R E F R I G E R AT I O N E X P E RT S S I N C E 1 8 9 2 THE ORIGINAL REFRIGERATION EXPERTS SINCE 1892
IMPORTANT SAFETY INSTRUCTIONS Important Safety Instructions Warnings and safety instructions appearing in this guide are not meant to cover all possible conditions and situations that may occur. Common sense, caution, and care must be exercised when installing, maintaining, or operating this appliance. Recognize Safety Symbols, Words, and Labels. ! WARNING WARNING - You can be killed or seriously injured if you do not follow these instructions.
TABLE OF CONTENTS Tip: Click on any section below to jump directly there Safety Important Safety Instructions Installation Unpacking Your Appliance Electrical Side-by-Side & Stacking Installations Installing the anti-tip device Door Reversal Installing The Water Supply Service Obtaining Service Product Liability Warranty Claims Ordering Replacement Parts R600a Specifications System Diagnosis Guide Service Mode Thermistor Warranty 3
UNPACKING YOUR APPLIANCE ! WARNING EXCESSIVE WEIGHT HAZARD Use two or more people to move product. Failure to do so can result in personal injury. Remove Interior Packaging Your appliance has been packed for shipment with all parts that could be damaged by movement securely fastened. Remove internal packing materials and any tape holding internal components in place. The owners manual is shipped inside the product in a plastic bag along with the warranty registration card, and other accessory items.
ELECTRICAL Electrical Connection A grounded 115 volt, 15 amp dedicated circuit is required. Do not remove ground prong This product is factory equipped with a power supply cord that has a three-pronged, grounded plug. It must be plugged into a mating grounding type receptacle in accordance with the National Electrical Code and applicable local codes and ordinances (see figure below).
Side-by-Side Installation 3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver. Two units may be installed side-by-side. Cutout width for a side-by-side installation is the cutout Tighten screws fully. 4. Gently push units into position. Be careful not to dimension of a single unit times two. No trim kit is required. However, 1/4" (6 mm) of space entangle the electrical cord or water line, if applicable. 5.
Anti-Tip Bracket 1. Slide unit out so screws on top of unit are easily accessible. 2. Remove the two screws from the opposite side of the hinge assembly using a T-25 Torx driver (see below). 3. Place bracket over holes and attach to unit with two screws removed in step 2 using a T-25 Torx driver. Tighten screws fully. 4. Gently push unit into position. Be careful not to entangle the electrical cord or water line, if applicable. 5.
Door Adjustments REVERSING THE DOOR HINGE COVER Location of the unit may make it desirable to mount the Hinge cover included with the literature bag is optional. door on the opposite side of the cabinet. The hinge hardware will be removed and reinstalled on the opposite side of the cabinet. To install hinge cover: 1. Press hinge cover squarely over hinge. TO REVERSE THE DOOR Hinge Cover DOOR ALIGNMENT AND ADJUSTMENT Align and adjust the door if it is not level or is not sealing properly.
3. Remove door by tilting forward and lifting door off Install top hinge and door: bottom hinge. Retain shoulder washers; they will be reused. 4. 1. Remove three screws from hinge holes on the Install hinge with longer straight edge aligned to outside edge of cabinet. Do not tighten. opposite side. Reinstall into holes where the hinge was removed. (If utilizing supplied screw cover, install just one screw.) Remove bottom hinge: 1.
INSTALLING THE WATER SUPPLY ! CAUTION ! )DLOXUH WR XVH DQ DGHTXDWH GUDLQDJH V\VWHP ZLOO UHVXOW LQ surrounding water damage and/or poor ice production. CAUTION Observe and follow all local building codes when installing this ice machine and drain lines. C Water supply inlet L ! 11 WARNING 11»4" (3.2 cm) »16" (17mm) Electrical Shock Hazard Reasonable care and safe methods should be practiced.
INSTALLING THE WATER SUPPLY Optional Drain Pump. An optional drain pump is available if you have purchased an ice machine without one and do not have access to a gravity drain. Installation instructions are provided with the optional drain pump. Contact Marvel customer service at 616-754-5601 or your dealer for ordering. ! Drain line coiled and secured to the back of the cabinet. Uncoil, route to an appropriate drain and cut to length.
INSTALLING THE WATER SUPPLY Water Supply ! CAUTION Observe and follow all local building codes when installing this appliance. This ice machine must be connected to a potable cold water supply line. delivering water pressure between a minimum of 20 psi and a maximum of 120 psi. Use 1»4" copper tubing for your water supply which is available at any local hardware or plumbing supply store. Route the 1»4" copper tubing to suit your installation being sure not to kink the tubing.
INSTALLING THE WATER SUPPLY Procedure for Testing Drain System (both gravity and drain pump models) Drain pump models have a safety feature that will interrupt power to the unit if a high-limit condition occurs to prevent ÀRRGLQJ 7KLV VDIHW\ IHDWXUH FDQ EH LQLWLDWHG E\ D UHVWULFWLRQ LQ WKH GUDLQ V\VWHP DQG ZLOO FRQWLQXH XQWLO KLJK OLPLW FRQGLWLRQ is corrected, at which time power will be restored to the unit.
OBTAINING SERVICE If Service is Required: • If the product is within the first year warranty period please contact your dealer or call Marvel Customer Service at 616.754.5601 for directions on how to obtain warranty coverage in your area. • If the product is outside the first year warranty period, Marvel Customer Service can provide recommendations of service centers in your area. A listing of authorized service centers is also available at www.marvelrefrigeration.
Product Liability Field service technicians are authorized to make an initial assessment in the event of reported damages. If there are any questions about the process involved, the technician should call Marvel for further explanation. While inspecting for defects or installation issues, photos should be taken to document any damages or issues found.
Warranty Claims Units must be registered prior to warranty submittal. The following information defines the parameters for filing a warranty claim: com. A proof of purchase is required. We also accept the following information to update warranty: • Valid serial number needed • Valid model number needed • Claims must be submitted online at www. marvelservice.
Ordering Replacement Parts Parts may be o rdered online at partsformarvel.com Or contact: www.marvelrefrigeration.com (Servicers choose "Login" for service account). Phone Numb er: (616) 754-5601 NOTICE Use only genuine Marvel replacement parts. The use of non-Marvel parts can reduce performance, damage the unit, and void the warranty. Warranty parts will be shipped at no charge after Marvel confirms warranty status. Please provide the model, serial number, part number and part description.
R-600A Specifications & Handling Gloves and Eye Protection must be used. ,., . ���· ' R-600a is considered non-toxic, but is flammable when mixed with air. Keep a dry powder type fire extinguisher in the work area. R-600a is heavier than air, do not allow any leakage/migration to low areas such as basements and stairs. RISK Of FIRE OR EXPLOSION. FLAMMABLE REFRIGERANT USED. TO BE REPAIRED ONLY BY TRAINED SERVICE PERSONNEL DO HOT PUNCTURE REFRIGERANT TUBING RISK Of FIRE OR EXPLOSION.
IA WARNING I Only skilled and well trained service technicians permitted to service R-600a equipped products. R-600A SPECIFICATIONS/LABELING R-600a equipped products are labeled (both the unit and the compressor). R-600a is colorless and odorless. All tools and equipment must be approved for use with R-600a refrigerant. R-600a is considered non-toxic, but is flammable when mixed with air. Local, state and federal laws, standards must be observed along with proper certification and licensing.
Evacuate/reclaim via the piecing pliers to ensure the When re-brazing, the system must be purged with dry system is empty of R-600a before any system work is nitrogen and at least one access point open to the performed. atmosphere. When re-brazing, proper ventilation is required along with constant monitoring for the presence of R600a refrigerant. GAS LEAi< The filter dryer must be replaced any time the sealed system is serviced.
The low side of the refrigeration system (evaporator, Proper ventilation during service is required. compressor and suction line) must be leak tested with the compressor off (equalized pressure). Never apply a torch to a charged R-600a refrigeration system. RECHARGING No air is ever to be allowed inside the refrigeration system (R-600a refrigerant or dry nitrogen only). Use OEM replacement service parts and do not alter the construction of the unit.
System Diagnosis Guide REGRIGERATION SYSTEM DIAGNOSIS GUIDE Capillary Tube Evaporator Wattage Very hot Warm Cold Normal Slightly warm to hot Hot to warm Cool Cold Higher than normal Hot Warm Warm Extremely cold near inlet - Outlet below room temperature Lower than normal Somewhat Warmlower than near room normal vacuum temperature Very hot Top passes Room temperature warm Lower (cool) or colder passes cool (near room temperature) due to liquid Extremely cold near inlet - Outlet below room
SERVICE MODE GUIDE SERVICE MODE GUIDE ([LW 7KHUPLVWRU WHPSHUDWXUH QRW LQFOXGLQJ RɞVHWV 7KHUPLVWRU WHPSHUDWXUH QRW LQFOXGLQJ RɞVHWV 7KHUPLVWRU WHPSHUDWXUH QRW LQFOXGLQJ RɞVHWV 7KHUPLVWRU WHPSHUDWXUH QRW LQFOXGLQJ RɞVHWV 7KHUPLVWRU RɞVHW 7KHUPLVWRU RɞVHW 7KHUPLVWRU RɞVHW 7KHUPLVWRU RɞVHW 9. Thermistor 2 set point 7KHUPLVWRU VHW SRLQW 11. Thermistor 4 set point.
E3: Thermistor 3 open. 25. E4: 7KHUPLVWRU RSHQ 'RHV QRW DSSO\ WR WKLV PRGHO 26. Does not apply to this model E5: Thermistor 1 shorted. 27. FACTORY TEST MODEL MAIN SOFTWARE E6: Thermistor 2 shorted. 2ɞ 2Q E7: Thermistor 3 shorted. 28. COMPRESSOR RPM E8: 7KHUPLVWRU VKRUWHG 'RHV QRW DSSO\ WR WKLV 29. FREEZE TIME ADJUST (MODEL 54 ONLY) PRGHO HARVEST TIME ADJUST (MODEL 54 ONLY) E9: 'RRU ORZHU RSHQ 31.
Thermistors Evaporator Thermistor Thermistors are used for various temperature readings. If the evaporator thermistor fails, the unit will rely on a Thermistors provid e reliable temperature readings preset defrost timer during defrost cycles. The unit will using a resistance which varies based on surrounding otherwise operate normally. Refer to defrost section. temperatures. If a faulty thermistor is suspected it may be tested using an accurate ohmmeter.
HOUSEHOLD PRODUCT WARRANTY Marvel Refrigeration (Marvel) Limited Warranty ONE YEAR LIMITED PARTS & LABOR WARRANTY For one year from the date of original purchase, this warranty covers all parts and labor to repair or replace any part of the product that proves to be defective in materials or workmanship. For products installed and used for normal residential use, material cosmetic defects are included in this warranty, with coverage limited to 60 days from the date of original purchase.
www.marvelrefrigeration.com Marvel Refrigeration 1260 E. Van Deinse St. Greenville MI 48838 616.754.5601 All specifications and product designs subject to change without notice. Such revisions do not entitle the buyer to corresponding changes, improvements, additions, replacements or compensation for previously purchased products.