Use and Care Guide
DRAIN PUMP REMOVAL INSTRUCTIONS
24
Figure 28
Unscrew the leveling leg so
the end of the threads is ush
with the top of the nut insert.
Remove these 4 hose
clamps, then remove the 3
tubes from the drain pump
It may be necessary to disconnect
this electrical connection on factory
installed drain pumps
Drain pump
ground wire
connection
Drain Pump Removal Instructions:
1. Unplug ice machine from the electrical supply and re-
move the rear access cover from the ice machine. (See
page 6 for instructions).
2. Unscrew the leveling leg in the back corner until the
end of the threaded portion is ush with the threaded
nut insert in the base. (see Figure 28 ).
3. Unscrew the 4 hose clamps and remove the 3 hoses
from the front of the drain pump. (See Figure 28).
4. Rotate the drain pump and remove from the ice ma-
chine, (See Figure 27). It may be necessary to discon-
nect the ground wire connection in the back ange of
the cabinet. (See Figure 28).
5. Disconnect the ice machine power cord from the drain
pump (See Figure 29).
6. To drain water from the pump follow step 13 through 15
on page 22.
7. Installation of drain pump is reverse of this procedure.
Figure 27
Rotate drain pump
and remove from
back of ice machine.
Drain valve