Instructions for Use A-dec 571/572 and 6300 Dental Light
Copyright © 2013 A-dec Inc. All rights reserved. A-dec Inc. makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. A-dec Inc. shall not be held liable for any errors contained herein or any consequential or other damages concerning the furnishing, performance or use of this material. The information in this document is subject to change without notice.
CONTENTS 1 Introduction.................................................................................. 3 About Your Dental Light.................................................................................................................3 2 Basic Operation ............................................................................. 5 Power On/Off and Intensity Switches ..........................................................................................5 Touchpad Controls......................
A-dec 571/572 and 6300 Dental Light Instructions For Use 2 86.0612.
INTRODUCTION 1 Thank you for choosing A-dec equipment. This guide contains basic operating instructions, adjustments, and maintenance for your A-dec dental light. About Your Dental Light A-dec dental lights include a number of features designed to make your job easier. The balanced light gives a clear view of tooth surfaces, the precision-balanced arm allows for smooth positioning, and a diagonal axis lets you angle the light head just where you need it. Figure 1.
A-dec 571/572 and 6300 Dental Light Instructions For Use Figure 2. Dental Light Features D E C F B G H A 4 Item Description A Light handle B On/Off Switch C Intensity Switch D Flexarm E Switch Housing F Light Yoke G Light shield H Nosepiece 86.0612.
2 B A S I C O P E RA T I O N Power On/Off and Intensity Switches The dental light head features a large on/off switch so you can easily activate the light using the back of your hand or elbow. An intensity switch allows you to toggle between three intensities: high, medium, and composite (see Figure 3). Figure 3. Power On/Off and Intensity Switches A B (A) Intensity Switch; (B) On/Off Switch 86.0612.
A-dec 571/572 and 6300 Dental Light Instructions For Use Touchpad Controls A-dec dental lights can be operated from the A-dec 300 or A-dec 500 touchpad. To turn the light on, press the dental light button on the touchpad (see Figure 4). To turn the light off, press and hold the light button. Figure 4.
Basic Operation Auto On/Off Feature (A-dec 300/500 systems only) The dental light includes an auto on/off feature that automatically turns the light on when the chair back reaches an operating position. When the chair back moves out of an operating position, it automatically turns off. • To turn off the auto on/off feature, press and hold the program and light buttons simultaneously (see Figure 4). A beep confirms the dental light on/off function is off.
A-dec 571/572 and 6300 Dental Light Instructions For Use Circuit Breaker Locations Under abnormal conditions, the dental light circuit breaker interrupts the flow of electricity. If the circuit breaker should trip, reset it by pushing the circuit breaker. The circuit breaker for your dental light is located on the power supply, which varies by product (see Table 1). Table 1.
ADJUSTMENTS AND MAINTENANCE 3 Always turn off the dental light and allow it to cool completely before maintenance or service. WARNING Focus Adjustment The light is factory adjusted for proper illumination focus at 27 inches (700 mm) from the oral cavity. However, you can quickly and easily adjust the light focus (between 18 and 31 inches [460 mm and 790 mm]) to best suit your needs. To adjust: 1. Place a white towel over the chair headrest to represent the oral cavity. 2.
A-dec 571/572 and 6300 Dental Light Instructions For Use Light Head Adjustment Adjust the light head tension if it is difficult to position, moves too easily, or tends to slip out of position (see Figure 6). Figure 6. Light Head Rotation A B C (A) Left/Right Rotation; (B) Diagonal Rotation; (C) Up/Down Rotation Horizontal Rotation 1. Use a hex key to make left/right rotation adjustments, beginning with the top screw on both sides of the switch housing (see Figure 7). 2.
Adjustments and Maintenance Diagonal Axis Rotation For diagonal axis rotation, adjust the screws at the bottom of the switch housing (see Figure 8). 1. If the light head moves too easily, or tends to drift out of position, increase the tension by turning the screw right. 2. If the light head is difficult to move, loosen the tension by turning the screw left. 3. To eliminate all movement in the diagonal axis, tighten the adjustment screw until it is tight. Figure 8.
A-dec 571/572 and 6300 Dental Light Instructions For Use Vertical Rotation 1. Loosen the setscrew (see Figure 9). 2. Remove the light yoke plug. 3. Use a large flat-blade screwdriver to turn the adjustment screw under the light yoke plug. 4. If the light head moves too easily, or tends to drift out of position, increase the tension by turning the screw right. 5. If the light head is difficult to move, loosen the tension by turning the screw left. 6.
Adjustments and Maintenance Figure 10. Holder and Spare Bulb A B (A) Holder; (B) Bulb Follow these steps when replacing the bulb: 1. Turn off the light and allow it to cool. WARNING To avoid burning your fingers, allow the light shield to cool before removing. Never operate the dental light with the light shield removed. The light shield contains UV blocking additives. The light shield is also your protection in the unlikely event that the bulb shatters. 2.
A-dec 571/572 and 6300 Dental Light Instructions For Use Maintenance Parts Table 2 lists the parts you may use during routine maintenance. Table 2. Maintenance Parts List Description Part Number Bulb Only 041.709.00 Light Shield and Nosepiece 28.0503.02 Light Shield 28.0503.01 Clean / Maintain Barrier Protection CAUTION patient. If you use barriers, always replace the barrier film after each A-dec recommends barrier protection for all applicable touch and transfer surfaces.
A P P E N D I X : WA R RA N T Y AND SPECIFICATIONS A Warranty A-dec warrants all products against defects in materials or workmanship for one year from time of delivery. A-dec’s sole obligation under the warranty is to provide parts for the repair, or at its option, to provide the replacement product (excluding labor). The buyer shall have no other remedy. All special, incidental, and coincidental damages are excluded. Written notice of breach of warranty must be given to A-dec within the warranty period.
A-dec 571/572 and 6300 Dental Light Instructions For Use Specifications Operating Specifications • Operating voltage: 100, 120, or 240V • Focal range: Adjustable; 18 - 31 inches (457 - 787 mm) • Bulb: Quartz Xenon Halogen, single-end prongs • Lamp rating: 17V/ 95W • Color temperature: 5000 Kelvin • Light pattern: 3.3" x 6.3" at 27.
A-dec Headquarters 2601 Crestview Drive Newberg, OR 97132 USA Tel: 1.800.547.1883 Within USA/Canada Tel: 1.503.538.7478 Outside USA/Canada Fax: 1.503.538.0276 www.a-dec.com International Distribution Centers A-dec United Kingdom Authorized EU Representative Austin House, 11 Liberty Way Nuneaton, Warwickshire CV11 6RZ England Tel: 0800 ADECUK (233285) Within UK Tel: +44 (0) 24 7635 0901 Outside UK www.a-dec.co.uk A-dec Australia Unit 8 5-9 Ricketty Street Mascot, NSW 2020 Australia Tel: 1.800.225.