User manual
10 SynchroZap QX250
For independent control, each fixture must have its own address as in example 1. If inde-
pendent control is not required, 2 or more SynchroZaps may share the same address: they
will receive the same instructions and behave identically. In example 2, units 1 and 2 will
behave the same, as will units 3 and 4.
1.
Look up the DIP-switch setting for the selected address on page 23. You can
also find the setting by subtracting pin values, shown below, until the total of
the values equals the address. Start with the highest pin value that can be
subtracted and continue until there is no remainder.
2.
Set the DIP-switch by flipping the OFF pins up and the ON pins down with
a small screwdriver or similar tool.
Example 1: 4 units, 6-channel control
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
unit 1
address = 1
unit 2
address = 7
unit 3
address = 13
unit 4
address = 19
Example 2: 2 sets of 2 units with 6-channel control and
4 units with 1-channel control
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
units 1 and 2
address = 1
units 3 and 4
address = 7
unit 5
unit 6
unit 7
unit 8
pin 1 2 3 4 5 6 7 8 9 10
value
1
2
4
8
16
32
64
128
256
special
DIP-switch pin values
102
3
4 51 86 7 9
On
Example: Channel 50,
6-channel mode
Pins 2, 5 and 6 ON
channel
- value of
pin 6
50
- 32
remainder
- value of
pin 5
18
- 16
remainder
- value of
pin 2
2
- 2
remainder
0
102
3
4 51 86 7 9
On
Example: channel 100
1-channel mode
Pins 3, 6, 7, 9, 10 ON
channel
- value of
pin 7
100
- 64
remainder
- value of
pin 6
36
- 32
remainder
- value of
pin 3
4
- 4
remainder
0