User manual

14 Martin DMX 5.3 and RDM 5.5 Splitters user manual
Table 1 shows some pin identification schemes. Consult a qualified
electrician if you have any doubts about proper installation.
Martin RDM 5.5 Splitter
The RDM 5.5 Splitter is supplied with a blue Neutrik PowerCon NAC3FCA
cable-mount connector for power input. The user must supply a suitable
length of power cable that meets the requirements listed on page 5 and
install the PowerCon connector on it as described below. The user must
then either hard-wire the power cable to the building’s electrical
installation, providing an easily accessible power on/off switch close to the
device, or install on the power cable a grounding-type (earthed) mains
plug that is suitable for the local power outlets, following the power plug
manufacturer’s instructions. Table 1 shows some pin identification
schemes. Consult a qualified electrician if you have any doubts about
proper installation.
Installing a Neutrik NAC3FCA power connector on a power cable
To install a Neutrik NAC3FCA input
connector on a power cable:
1. Slide the bushing over the cable.
2. Slide the white chuck over cables
with a diameter (D
a
) of 5 - 10 mm
(0.2 - 0.4 in.), or the black chuck
over cables with a diameter of 10
- 15 mm (0.4 - 0.6 in.).
3. Prepare the end of the cable by
stripping 20 mm (0.8 in.) of the cable’s outer jacket.
4. Strip 8 mm (1/3 in.) from the end of each of the wires.
Wire
(US system)
Wire
(EU system)
Pin Marking Screw color
black brown live “L” yellow or brass
white blue neutral “N” silver
green yellow/green ground
or
green
Table 1: Power plug pin identification
Chuck BushingHousing Insert