User guide
 16 MAC Viper Profile Safety and Installation Guide
6. Close the lamp access cover and tighten the screw to secure the cover before reapplying power.
7. After installing a new lamp, reset the LAMP ON TIME counter in the control menu.
Lamp adjustment
Warning! Adjust the lamp with the fixture cool. The fixture may become hot during adjustment, so 
wear heat-resistant safety gloves.
As well as giving uneven projection, a significant hot-spot in the beam will focus extra heat onto optical 
components and may cause damage that is not covered by the product warranty.
After fitting a new lamp, adjustment may be required to obtain an even beam. 
To adjust the lamp:
1. If the fixture has been in use, douse the lamp but leave power applied. Allow the fixture to cool for at 
least 30 minutes. If the fixture is powered off, apply power and allow the fixture to reset.
2. Set zoom to wide so 
that it is easier to see 
any unevenness in the 
projection. Strike the 
lamp and open the 
shutter.
3. Aim the fixture at an 
even surface and 
make sure that no 
further commands can 
be sent by DMX.
4. See Figure 11. Turn 
the three Torx 20 lamp 
adjustment screws C, 
D and E to obtain the 
most even beam.
Figure 10: Lamp removal / refitting
B
B
OPEN
LOCKED
Figure 11: Lamp adjustment
E
C
D