User guide
 16 MAC Viper Profile Safety and Installation Guide
6. Close the lamp access cover and tighten the screw to secure the cover before reapplying power.
7. After installing a new lamp, reset the LAMP ON TIME counter in the control menu.
Lamp adjustment
Warning! Adjust the lamp with the fixture cool. The fixture may become hot during adjustment, so 
wear heat-resistant safety gloves.
As well as giving uneven projection, a significant hot-spot in the beam will focus extra heat onto optical 
components and may cause damage that is not covered by the product warranty.
After fitting a new lamp, adjustment may be required to obtain an even beam. 
To adjust the lamp:
1. If the fixture has been in use, allow it to cool for at least 30 minutes to avoid the danger of burns, and 
wear heat-resistant safety gloves.
2. Apply power, allow the 
fixture to reset, then 
set zoom to narrow, 
turn on the lamp and 
open the mechanical 
shutter.
3. Aim the fixture at an 
even surface and 
make sure no further 
commands can be 
sent by DMX.
4. See Figure 11. Turn 
the three Torx 20 lamp 
adjustment screws C, 
D and E to obtain the 
most even beam.
Figure 10: Lamp removal / refitting
B
B
OPEN
LOCKED
Figure 11: Lamp adjustment
E
C
D