Connecting to an AC mains power source
The MAC Viper Profile power cable can be hard-wired to a building installation circuit or fitted with a cord
cap (mains plug) to allow connection to local AC mains power outlets. If you install a cord cap (mains plug),
install a grounding-type (earthed) plug, following the plug manufacturer’s instructions. Table 1 shows some
possible mains power pin identification schemes; if the pins are not clearly identified, or if you have any
doubts about proper installation, consult a qualified electrician.
Applying power
See Figure 7. To apply power to
the MAC Viper Profile, check that
the tilt lock is released, that the
base is held securely, and that
personal safety will not be put at
risk when the lamp strikes and the
fixture moves, then set the power
on/off switch B to I (On).
Check that the mains power on/off
switch B is set to O (Off) before
inserting or removing the power
input connector at the input
socket A, otherwise you may
cause arcing at connector
terminals that can damage them.
Shutting down power
For optimum lamp life, wait at
least 5 minutes after striking a
discharge lamp before dousing
the lamp.
It is also good practise to douse the lamp a few minutes before shutting down power. This gives the fans
time to cool the fixture down.
Wire Color Pin Symbol Screw (US)
brown live L yellow or brass
blue neutral N silver
yellow/green ground (earth) green
Table 1: Cord cap connections
IN
IN
OUT
OUT
DMX
DMX
WARNING
WARNING:
Disconnect from
Disconnect from
mains before
mains before
servicing.
servicing.
ATTENTION
ATTENTION:
Déconnecter du
Déconnecter du
secteur avant
secteur avant
entretien.
entretien.
MAINS INPUT
MAINS INPUT
MAINS
MAINS
SWITCH
SWITCH
AC supply
AC supply
Brown = Live
Brown = Live
Blue = Neutral
Blue = Neutral
Yel/Green = Earth
Yel/Green = Earth
Figure 7: Mains input socket and mains power on/off switch