Specifications
244 LightJockey Help file - (C) Martin Professional 2010
LightJockey Help
Intensity Value Range as well as Limit GM to intensity range.
Blackout values (static function)
Fill out this static function to enable LightJockey to blackout the fixture. The values are sent when
Blackout is enabled directly or via the Blackout when Grand Master at 0 function.
Fixture lamp control
Lamp On Values (static function)
Enable the lamp on function and fill out the static values to enable LightJockey to send a lamp on
command to the fixture.
Auto LampOn Time
Some fixtures may require a lamp on command to be held for a minimum time before activating. To
ensure that the auto lamp on function holds the command for the required duration, enter the required
minimum time in this field (in milliseconds).
Lamp Off Values (static function)
Enable the lamp off function and fill out the static values to enable LightJockey to send a lamp off
command to the fixture.
Both lamp on and lamp off commands are available from the fixtures lamp control. Note that these
commands are intended to be used with fixtures that are equipped with discharge lamps that requires
a certain cool down time before the lamp can be re-struck. Profiles for fixtures equipped with halogen
lamps should use the normal intensity/shutter commands for lamp control.
See also defining the generic fixture 2 profile, dynamic functions, static functions
The pan & tilt tab
The pan & tilt tab