Specifications
101 LightJockey Help file - (C) Martin Professional 2010
LightJockey Help
into scenes will be overridden.
Haze Control
The haze control may be used to set an output and fan level on a DMX hazer without the need to
program the level into scenes. The hazer controls does not use the timer function, the output and fan
levels set are always active and are sent continuously to the hazer. The level and fan values will
override any levels programmed into scenes as soon as the output level or fan level is set above 0.
Preferences menu
View haze control - view or hide the haze controls (hiding does not disable the haze controls).
Enable timer on startup - the smoke timer will be activated as soon as LightJockey starts up.
Reset cycle on smoke- clicking Smoke will automatically reset the cycle time.
Smoke button use level - the output generated by clicking smoke is identical to the level set with the
level fader. If this option is disabled the smoke machine will be instructed to smoke with max output
(DMX value 255) when the smoke button is pressed.
Smoke button toggle X seconds -- these options makes it possible to output smoke for a longer time
using the Smoke button without holding down the mouse button. For example if the 'Smoke button
toggle 4-5 seconds' option is selected the button will stay pressed for another 4-5 seconds after the
mouse button is released. This option only works when clicking the smoke button directly, not when
the smoke button is activated through hotkey or via the 2532 or DMX-in.