User manual
RUSH MH 4 Beam User Manual 43
Control and Programming
Control system .....................................................................................DMX
DMX channels .......................................................................................... 13
Setting and addressing .................... Control panel with backlit LCD display
DMX compliance ....................................................... USITT DMX512/1990
16-bit control ..................................................................... Dimming, pan, tilt
Pan and tilt speed .............. Adjustable via onboard control panel and DMX
Position correction system ........................................................ Pan and tilt
Optics
Beam angle .............................................................................................. 3°
Construction
Color .................................................................................................... Black
Housing .................................... High-impact flame-retardant thermoplastic
Protection rating .................................................................................. IP 20
Installation
Mounting points .................... Four quarter-turn bracket mounting points
Minimum distance from illuminated surfaces ....................... 6.5 m (21.3 ft.)
Location ............. Indoor use only, must be fastened to surface or structure
Orientation ............................................................................................. Any
Connections
AC power in/out .................................................................. Neutrik PowerCon
DMX data in/out ................................................... 3-pin & 5-pin locking XLR
Electrical
AC power ....................................................... 100-240 V nominal, 50/60 Hz
Fuse .................................................................................................... T6.3A
Power supply unit .............................. Auto-ranging electronic switch-mode
Typical power and current
110 V, 60 Hz ........................................................... 2.2 A, 234 W, PF 0.996
230 V, 50 Hz ........................................................... 1.1 A, 231 W, PF 0.996
Measurements made at nominal voltage. Figures are typical, not maximum.
Allow for a deviation of +/- 10%.
Thermal
Cooling ........................................................................................ Forced air
Maximum ambient temperature (T
a
max.) ............................ 40° C (104° F)
Minimum ambient temperature (T
a
min) .................................... 0°C (32° F)
Total heat dissipation (calculated, +/- 10%) ............................. 800 BTU/hr.