MPU-08 Connection procedure
Important Note: ‘Return’ lines 
The MPU-08 is designed for use with larger quantities of Atomic Colors fixtures, and 
in bigger installations where the cable runs a longer. 
In order to reduce the voltage drop in these longer cable runs, an XLR-4 ‘Return’ 
cable must be installed in the s
y
stem, so the cablin
g
 forms a continuous loo
p
.
1.  Rig the combined Atomic 3000DMX and Atomic Colors fixtures in their desired 
positions, ensuring that you use the safety wire as a secondary means of attachment. 
2.  Connect your source of DMX data to the XLR-5 input socket on the front of the MPU-08. 
3.  Using an XLR-4 cable, connect the ‘out’ of ‘Power outlet 1’ on the MPU-08, to the XLR-
4 input on the Atomic Colors fixture #1. 
4.  Using another XLR-4 cable, connect the XLR-4 output of Atomic Colors fixture #1, to 
the XLR-4 input on the Atomic Colors fixture #2. 
5.  Repeat step 4, until you have a maximum of four Atomic Colors fixtures connected 
together. 
6.  Connect the XLR-4 output on the last Atomic Colors fixture to the ‘Return’ of ‘Power 
outlet 1’ on the MPU-08. 
7.  Repeat steps 3-6 using cables and fixtures connected to ‘Power outlet 2’ on the MPU-08, 
8.  Connect the AC supplies to the MPU-08 and the Atomic 3000DMX unit(s).
Note: Proper connection of the units to the power supply is important! 
 Please follow these basic rules. 
•  Use the proper type of cable and connectors. 
•  Keep cable runs as short as possible, to reduce line loss. 
•  The total cable length for run should not exceed 75 M (245 ft), including the return line. 
•  Always use a return cable for each cable run. This will ensure balanced LV power to all 
units. 
• 
Before operating the Atomic strobe, make sure the power supply for the Atomic Colors 
is connected, and switched on.
Atomic Colors User Manual Connecting the unit  12