User manual
6 MAC 2000 Performance II
Protection from burns and fire
• Never attempt to bypass the thermostatic switch or fuses. Always replace defective fuses with ones of the
specified type and rating.
• Keep all combustible materials (for example fabric, wood, paper) at least 1.0 meter (39 inches) away from
the fixture. Keep flammable materials well away from the fixture.
• Do not illuminate surfaces within 1.0 meter (39 inches) of the fixture.
• Provide a minimum clearance of 0.1 meters (4 inches) around fans and air vents.
• Never place filters or other materials over the lens.
• The exterior of the fixture can get very hot. Allow the fixture to cool for at least 5 minutes before handling.
• Do not modify the fixture or install other than genuine Martin parts.
• Do not operate the fixture if the ambient temperature (Ta) exceeds 40° C (104° F).
Protection from injury due to falls
• Do not lift or carry the fixture alone.
• When suspending the fixture, verify that the structure can hold at least 10 times the weight of all installed
devices.
• Verify that all external covers and rigging hardware are securely fastened and use an approved means of
secondary attachment such as a safety cable.
• Block access below the work area whenever installing or removing the fixture.