User manual

52 MAC 2000 Performance II
D
ISPLAY
MESSAGES
Message Appears when... What to do
 (Reset)
... the fixture is indexing effects at startup. Wait for reset to complete.
 (Serial reset)
... the fixture has received a reset command from the
controller.
Wait for reset to complete. Set
 to off to prevent
accidental reset commands.

... the effects have been indexed and are moving to
their default positions.
Wait a few moments.

...the lamp access cover is not fully closed.
Verify that the lamp access cover is
locked in place.
 (Lamp error)
... the lamp doesn’t ignite within 10 minutes of receiving
the ‘Lamp ON’ command. Likely reasons are a missing
or defective lamp, or insufficient AC voltage.
Check the lamp. Check that the
voltage and frequency settings
match the local supply.
 (Memory error) ...the EEPROM memory cannot be read.
Contact Martin service personnel for
assistance.
 (Short error)
... the fixture detects the lamp is on but no ‘Lamp ON’
command has been received. This can occur if the
lamp relay is stuck or if the lamp-power feedback circuit
fails. The fixture may be operated but remote lamp
on/off may be affected.
Contact Martin service personnel for
assistance.
 (Base temperature error)
 (Head temperature error)
... there is a fault with the temperature sensor in the
base or head.
Contact Martin service personnel for
assistance.
 (Feedback error pan)
 (Feedback error tilt)
 (Feedback error pan/tilt)
...pan (
), tilt () or both ()
feedback circuits are malfunctioning. It will still be
possible to operate the fixture, though it goes into a
“safe” mode where maximum speed is reduced, thus
preventing the fixture from losing track of its home
position (losing step).
Contact Martin service personnel for
assistance.
 (Pan time-out)
 (Tilt time-out)
 (Cyan time-out)
 (Magenta time-out)
 (Yellow time-out)
 (CTC time-out)
 (Focus time-out)
 (Zoom time-out)
...the electric indexing circuit is malfunctioning. The
fixture will, after the time-out, establish a mechanical
stop, and continue to work normally.
Reset fixture again. Contact Martin
service personnel if problem
continues.
 (Gobo wheel time-out)
 (Gobo wheel rotation time-out)
 (Animation wheel position time-out)
 (Animation wheel rotation time-out)
 (Effect wheel time-out)
 (Frame rotation index time-out)
...the magnetic-indexing circuit malfunctions (e.g.
sensor defective or magnet missing). After the time-out,
the effect in question stops in a random position.
Reset fixture again. Contact Martin
service personnel if problem
continues.
 
 
 




...an effect does not move away from the index position
under reset, a sensor or micro-switch circuit is shorted,
or a micro-switch is stuck or connected incorrectly.
Contact Martin service personnel for
assistance.

...there is an on board RAM memory error.
Contact Martin service personnel for
assistance.
 ...there is an on-board programming error.
Contact Martin service personnel for
assistance.

...light sensor 1 is in error status.
Contact Martin service personnel for
assistance.

---there is a thermoswitch error or a jumper on PL47
error.
Contact Martin service personnel for
assistance.
Table 4: Display messages