User manual
38 MAC 2000 Performance II
Cleaning or replacing the air filters
1 Disconnect the fixture from power. On each side of the head, remove the 2 screws that hold the side cover
using a Torx-20 screwdriver. Slide the cover forward to remove. Lift the filter off of the cover.
2 Clean the filters with a vacuum or compressed air, or replace them. If they are saturated with smoke fluid,
etcetera, soak them in warm soapy water and blot dry.
3 Place the filters on the covers and replace the covers.
Software installation
Software updates are installed in the MAC 2000 Performance II using a Martin MP-2 Uploader or a
LightJockey 4064 DMX interface card. The procedure is found in the MP-2 user manual and the Martin
Software Uploader online help file.
Requirements
The following are required in order to install software.
• The MAC 2000 Performance II update file, available for download from the User Support Area of the Martin
web site (http://www.martin.dk).
• The Martin Software Uploader program, version 4.0 or later, available for download from the User Support
Area of the Martin web site.
• A Martin MP-2 Uploader connected to a Windows 95/98/ME/2000/XP PC, or a LightJockey Controller (DJ or
Club) with 4064 DMX Interface card.
Preventing software updates
Software updates are enabled by default, but you can disable this by setting the Write jumper (see “Circuit
board connections” on page 54) to disable.
Boot sector jumper
If the normal upload procedure does not work, or if the software update notes call for a boot sector update,
move the boot sector jumper on the printed circuit board to the BOOT position before uploading software.
S
ETTING
THE
BOOT
SECTOR
JUMPER
1 Disconnect the fixture from power.
2 Remove the top screws from the ends of the front side panel and tilt the
panel down to expose the main circuit board.
3 Using the appropriate diagram in “Circuit board connections” on page 54 or
the label inside the base, locate the BOOT jumper (PL16). Move the jumper
to the “BOOT” position.
4 Perform a boot mode upload. When the upload is complete, disconnect the
fixture from power and move the jumper back to the locked or normal
position.