Operating instructions

61D0008 7
Do not install replace
over carpeting.
CAUTION
FIREPLACE LOCATION
Plan for the installation of your replace. This includes determining
where the unit is to be installed, the vent conguration to be used, framing
and nishing details, and whether any optional accessories (i.e. blower,
wall switch, or remote control) are desired. Consult your local building
code agency to ensure compliance with local codes, including permits
and inspections.
The following factors should be taken into consideration:
This replace should have sufcient access for its safe operation and maintenance.
Locate a position where the ue system of the replace can be properly installed without damaging the integrity
of the building. e.g. cutting wall or ceiling joist (example: load-bearing framing members).
Install oor protection when the appliance is installed directly on tile or other combustible material.
Check replace and ue system clearance requirements.
Locate the replace in a large and open room that is centrally located in the house. This will optimize heat
circulation and comfort.
Locate replace away from frequently opened doors, central heat outlets or returns, or other places where air
movements may disturb the airow around the replace.

Locate replace near a load bearing wall. Make sure the support structure is strong enough or reinforced if
replace is to be trimmed with a heavy stone or brick facing and hearth extension.
This replace may be installed along a wall, across a corner, or use an exterior chase. See Figure 2 for suggested locations.
Location should be out of high trafc areas and away from furniture and draperies.
Never obstruct the front opening of the replace.
Do not install in the vicinity where gasoline or other ammable liquids are stored.
Vent pipe routing. See Venting section found in this manual for allowable venting congurations.
Minimum clearances to combustibles, side-wall, ceiling, woodwork, and windows must be maintained. See Clearances
Section in this manual.
Figure 2 - Suggested Fireplace Locations