MODEL AK-4 COMBUSTION AIR ASSEMBLY 
7. If the duct is the insulated type, push the insulation back from one end of
the duct approximately 2". See Figure 35.
8. Slip the exposed end of the duct over the starting collar on the replace.
9. Using the sheet metal screws provided, secure the duct end to the collar
attached to the replace.
10. Nail or screw the combustion air assembly to the surface of the wall.

      

necessary, splice the duct. Use a model 403-duct connector
to splice duct sections.
INSTALLING MODEL 403 DUCT CONNECTOR
1. Push insulation back approximately 2" from the end of each duct.
2. Slip each duct over duct connector until an equal length of connector extends into each duct.
3. Place duck clamp over the end of each duct. Tighten duct clamp down snuggly.
4. Push insulation back into place and over duct clamp.
Figure 35 - Installing Duct

Approximately
2"
Insulation
Duct
Connector
Duct Clamp
GAS APPLIANCE INSTALLATION
To reduce these risks to a minimum, read and follow the following important notices and instructions carefully.
1. The provision for a gas line is intended for connection to a decorative gas appliance which has an automatic shutoff device
and complies with the Standard for Decorative Gas Appliances for Installation in Vented Fireplaces, ANSIZ21.60. If a dec-
orative gas appliance is installed, it must be installed in accordance with the National Fuel Gas Code, ANSIZ223.1.
Improper installation or operation of a gas appliance in this replace can allow
unburned gas to leak out which will cause a re or explosion hazard, or the release
of poisonous carbon monoxide into the dwelling which can cause serious injury or
death to its inhabitants.
DANGER
Continued
Keep replace damper fully
opened at all times when
using a decorative VENTED
gas appliance.
WARNING