used in special installations (i.e. chase
installations)
CHIIMNEY INSTALLATION
1. Extend the regular chimney sections until the top of the chimney is 4"
below the total ue height desired. Do not snap the last section of inlet
air duct or largest diameter pipe in place until Step 3 is completed.
2. Remove the shingles from around the chimney so that the ashing
may be installed. Install the upper part of the ashing under the
shingles.
3. Set the ashing on the roof. Scribe a line around the ashing. Cut
1
/4" below the scribed line. This should increase the diameter of the
ashing outlet enough to allow the ashing to be placed over the
chimney. See Figure 25.
4. Snap the last section of inlet air duct in place. Slide ashing over the
chimney. Check for minimum clearances. Adjust chimney if neces-
sary to make minimum clearances.
5. Nail the ashing securely in place with eight (8) nails.
6. Seal crack between top of ashing and chimney with mastic. Leave
some extra mastic at this area to be used in step 8.
Be careful to avoid electrical shock
hazard when contacting wires to the
metal chimney components.
CAUTION
Use pliers and wear gloves when
handling the storm color The edge of
the storm color is sharp. If you are not
careful, you could cut your hands.
CAUTION
CHIMNEY CAP INSTALLATION 
Cut Off
1
/4"
below Scribed
Line

Flashing
Flashing


Model SC
Chimney Cap
Apply Mastic
Here
Storm Collar
Flashing
9. Place chimney cap into matching parts of the last chimney section. Push chimney cap down until the brackets on the
bottom of the chimney cap sits on the chimney pipe. Punch or drill
1
/8" diameter holes in the inlet air duct (chimney pipe)
where specied on the brackets. Fasten chimney pipe down with the No. 8 screws provided. Note: Do not penetrate

10. Check all the parts of the replace, chimney and chimney termination cap. Make sure none have been damaged or bent
during installation. Check to see that all parts have been properly installed.
Note: The metal used for chimney cap has a rust-protective coating but the cut edges of the parts are not


7. Place the storm collar around the chimney and put collar
together like a belt in belt loops. With the loops facing
up, slide the end of collar under the two loops on the
other end. Overlap the ends of the collar until it is tight
against the chimney. Bend the free end of the collar back
over the loops to hold the storm collar securely together.
Trim off the excess ends of the storm collar.
8. Slide storm collar down snugly against the ashing until
the excess mastic left in step six is forced up into crack
between the storm collar and chimney. This will make the
joint between the ashing and the chimney watertight.