Operating instructions
22 61D0008
7
9
/16"
7
1
/4"
22
1
/16"
15"
30°
A
A
3' min.
Flue Outlet
Height
Flue Outlet
Height
Flue Outlet
Height
3' min.
2' min. when
Dim. “A” is 10'
or Less
2' min. when
Dim. “A” is 10'
or Less
A
CHIIMNEY INSTALLATION
OFFSET INSTALLATION SEqUENCE
1. Install the rst SE30 elbow by placing the extended ue into the mating
part of the replace or chimney section. Push down until the outside of
inlet air duct of the elbow overlaps. Snap lock the elbow into the replace
or chimney section.
2. Nail the support straps to the framing member with a minimum of two (2)
8-penny nails per strap.
3. Install the sections of pipe between elbows until the proper number of
chimney sections have been installed.
4. Install the second elbow to return the run of the chimney to vertical.
5. Nail the support straps of the second elbow to a building frame member.
6. Continue installing the vertical portion of the chimney. See Figures 22
and 23.
Chimney
Center Line
Figure 23 - SF30 Firestop
Spacer
CHIMNEY CAP INSTALLATION
MODEL SC CHIMNEY CAP
Note: The proper chimney height is important to assure proper draft and safety.The chimney cap must
3
1
/8