When suspending the fixture, ensure that the supporting structure and all hardware used can hold at least
10 times the weight of all the devices they support.
Install the fixture only as described under “Physical installation” on page 11. In all truss-mount
installations where the fixture is not hanging vertically in ‘free hanging mode’, use a rigging clamp that
completely encircles the truss chord, and bolt the clamp directly to the fixture’s mounting bracket with a
grade 8.8 strength bolt and unworn self-locking nut. Do not use any type of clamp that does not
completely encircle the truss chord and do not use an omega bracket or any other intermediary rigging
hardware.
If you install the fixture in a location where it may cause injury or damage if it falls, install as described in
this manual a secondary attachment such as a safety cable that is approved by an official body such as
TÜV as a safety attachment for the weight that it secures.The safety cable must comply with EN
60598-2-17 Section 17.6.6 and be capable of bearing a static suspended load that is ten times the weight
of the fixture and all installed accessories. Fasten the safety cable to a secure anchoring point and to a
safety cable attachment point provided on the fixture and indicated in this manual so that the safety cable
will catch and hold the fixture if a primary attachment fails. Do not use any other part of the fixture as a
safety cable attachment point.
If the safety cable attachment point becomes deformed, do not install the fixture. Have the fixture repaired
by an authorized Martin service partner.
Check that all external covers and rigging hardware are securely fastened.