User manual
Table Of Contents
32 Atomic 3000 LED user manual
Onboard control menus
Default settings are indicated in bold print
Menu Item Options Notes
DMX ADDRESS 1 – XXX
DMX address (default address = 1). XXX means that the
DMX address range is limited so that the fixture will
always have enough DMX channels within the 512
available.
CONTROL
MODE
3 CHANNEL
Control of Beam strobe frequency, intensity and flash
duration.
4 CHANNEL
Control of Beam strobe frequency, intensity and flash
duration plus access to basic Beam effects.
EXTENDED
Control of Beam strobe frequency, intensity and
flash duration, basic Beam effects, RGB control of
Aura, fixture control/settings, pre-programmed FX.
FIXTURE ID 0 – 9999 User-definable fixture ID number.
PERSONALITY
DIMMER
CURVE
LINEAR Linear dimming curve
SQUARE LAW Square law dimming curve
INV SQUARE
LAW
Inverse square law dimming curve
S-CURVE S-curve dimming curve
STROBE
BEHAVIOR
LED Solid LED flash
XENON Flash simulates mains frequency cycles of a Xenon tube
VIDEO
TRACKING
ENABLED Color fading optimized for speed of changes
DISABLED Color fading optimized for smoothness
COOLING
MODE
REGULATE FANS Cooling fan speed thermostatically regulated
CONSTANT FAN
ULOW
Constant fan speed, ultra-low speed
CONSTANT FAN
LOW
Constant fan speed, low speed
CONSTANT FAN
MID
Constant fan speed, medium speed
CONSTANT FAN
HIGH
Constant fan speed, high speed
DMX RESET
OFF Disable reset via DMX
ON Enable reset via DMX
DISPLAY
DISPLAY SLEEP
ON / 2 MINUTES / 5 MINUTES / 10 MINUTES
Display remains on constantly / sleeps if no control
buttons pressed for 2, 5 or 10 minutes.
Default = 2 minutes.
DISPLAY
INTENSITY
Display intensity. Default=100%
DISPLAY
ROTATION
Display rotation NORMAL / 180°. Default= NORMAL
DISPLAY
CONTRAST
Display contrast 3% - 100%. Default=41%
ERROR MODE
NORMAL
Any errors detected are listed in display at 100%
intensity (regardless of DISPLAY INTENSITY
setting), status LED lights
SILENT Error messages not shown in display, status LED lights
DEFAULT
SETTINGS
FACTORY
DEFAULT
LOAD
Return all settings (except calibrations) to factory
defaults
NB: can take up to 2 minutes to complete!
CUSTOM 1
LOAD Load Custom Settings 1 from memory
SAVE
Save current fixture settings as Custom Settings 1
(overwrites existing Custom Settings 1)
CUSTOM 2
LOAD Load Custom Settings 2 from memory
SAVE
Save current fixture settings as Custom Settings 2
(overwrites existing Custom Settings 2)
CUSTOM 3
LOAD Load Custom Settings 3 from memory
SAVE
Save current fixture settings as Custom Settings 3
(overwrites existing Custom Settings 3)
Table 6: Control menu