User manual

Setup 19
- If the fixture is set to reduced cooling fan speed, increase the speed in the COOLING MODE menu.
- If necessary, clean the fixture, particularly the air vents.
- Check that there is sufficient airflow around the fixture. If possible, increase ventilation.
- If possible, provide reduced ambient temperature by moving the fixture away from sources of heat,
providing airflow from a cooler source of air, etc.
DISPLAY offers four options:
- DISPLAY SLEEP lets you set whether the control panel display remains on permanently or whether it
goes into sleep mode 2, 5 or 10 minutes after the last time a control panel button is pressed.
- DISPLAY INTENSITY lets you adjust the brightness of the control panel display backlighting. You can
set the intensity to a level from 10% to 100%.
- DISPLAY ROTATION lets you rotate the display for easier reading depending on fixture orientation.
- DISPLAY CONTRAST lets you adjust the contrast of the control panel display for easiest reading in
different display backlighting and ambient light conditions.
ERROR MODE enables or disables error warnings. If set to NORMAL, the display is activated and lights
up if the fixture needs to report an error. If set to SILENT, the fixture does not light the display with error
warnings but you can still read error messages by opening ERROR LIST in the SERVICE menu. In both
NORMAL and SILENT modes, the status LED lights amber to indicate a warning and red to indicate an
error.
Default and custom settings
The DEFAULT menu lets you reload the fixture’s factory default settings or save and recall up to three sets
of custom fixture settings. The savable settings comprise:
all the settings in the PERSONALITY menu,
the fixture’s DMX address, and
the fixture’s DMX control mode.
Fixture information readouts
The following fixture information can be called up in the display:
POWER ON TIME provides two counters:
- The TOTAL counter is not user-resettable and displays total hours powered on since manufacture.
- The RESETTABLE counter is user-resettable and displays the number of hours the fixture has been
powered on since the counter was last reset.
POWER ON CYCLES also provides two counters:
- The TOTAL counter is not user-resettable and displays the total number of power on/off cycles since
manufacture.
- The RESETTABLE counter is user-resettable and displays the number of power on/off cycles since the
counter was last reset.
COLOR SCROLLER lets you check whether the fixture has recognized that an Atomic Colors scroller has
been connected. If an Atomic Colors is fastened to the front of the fixture but not correctly connected to
the Atomic 3000 LED, starting the Atomic 3000 LED strobe can very quickly melt the gel string in the
Atomic Colors. Check the COLOR SCROLLER menu item immediately if you install an Atomic Colors
scroller. Also check it at any time if you are not 100% sure that the Atomic Colors is correctly connected.
SW VERSION displays the currently installed fixture software (firmware) version.
RDM UID displays the fixture’s factory-set unique ID for identification in RDM systems.
FAN SPEEDS provides separate status readouts from the fixture’s cooling fans.
TEMPERATURES provides separate PCB temperature readouts. If you display a readout and press
ENTER, you can choose to display the current temperature, the minimum or the maximum temperatures
since the last power cycle.