User's Manual Part 2

67
CROUP PARAMETER DEFAULT
1
Computer Type PC-AT
Interfaces *
2 Reading Mode Trigger
3
Beep Tone Mode 2.1k 1.Beep Medium
Beep Tone Mode 2.7k 1.Beep Medium
Capital lock Mode 3.Caplock Off
4 Preamble & Postamble Off
5 Accuracy Adjustment 2
6~9 Enable & Disable Code ID Off
10
Interblock Delay Oms
Inter-character Delay 140us
11
Keyboard Layout English(USA)
Terminator CR, CR+LF
12
Baud Rate 9600
Data Bits & Parity 8 Bit None
13
Stop Bits 1 stop bit
Handshaking None
ACK/NAK Off
Flow Control TimeOut 1 Sec
14
Level dutation of Mini Width 200us
Polarity Of Idle Condition High
Output of Wand Emulation Bar High/Space Low
Wave Form Full ASCII 39
15~16
Enable and Disable Symbologies
Code 32 Disable
China Postal Code Enable
UK Plessy Code Disable
Industrial 2 of 5 Disable
Matrix 2 of 5 Disable
Interleaved 2 of 5 Enable
Code 128 Enable
Cadabar Enable
Telepen Disable
UPC-A Enable
UPC-E Enable
EAN-8 Enable
EAN-13 Enable
MSI Disable
Code 39 Enable
Code 11 Enable
Code 93 Disable
EAN-128 Enable
IATA Disable
17
1
China Post Code
Enable/Disable Enable
Check Digits Disable CDV
Min Length 11 digits
Max Length 48 digits
2
Code 32
Enable/Disable Disable
Leading send/not send send
18 1
MSI
Enable/Disable Disable
Check Digits CDV & send CD
Check Digits Mode Single MOD 10
APPENDIX 1
DEFAULT TABLE 1