User's Manual

- 25 - - 26 -
MEMORY MODE
For memory version only
DATA FORMAT
Example:
To change Data Format to
<Barcode Data>, <Date>, <Time>
1. Scan [
Data Format
]
2. Scan [4], [2], [3] on page 9.
3. Scan [
Data Format
]
The default Data Format is
<Barcode Data> only
below are all items available for display and their codes:
For memory version only
Default is comma ( , ) . You may replace it with any alphanumeric
characters from the full ASCII table in Full User’s Manual.
Example: To change Field Separator to Semicolon ( ; )
1. Scan [
Field Separator
]
2. Scan [ ; ] from the full ASCII table.
3. Scan [
Field Separator
]
. R010$
*.R010$*
FIELD SEPARATOR
. R011$
*.R011$*
DATA FORMAT
2
4
Date
Barcode Data
Code Item Code Item
3 Time
After scanning the above barcode, the scanner will be able to collect barcode
data off-line. The barcode data will be stored in the format of:
< Date >, < Time >, < Barcode Data > < CR >
To retrieve stored data, please connect the scanner to the host with cable,
access removable storage device MiniScan from which you may open
or copy the file BARCODE.txt to your computer.
To delete ONE stored data, please scan below barcode :
. R005$
*.R005$*
. C035$
*.c035$*
MEMORY MODE
DELETE LAST DATA
To delete ALL stored data, simply delete the fileBARCODE.txtin the
removable storage device MiniScanuntil you hear two beeps.