2. Installation
DIP Switch Setup
When you control the camera through RS-485, before installation, you should set the DIP switches to
configure the camera ID, communication protocol.
Camera ID setup
ON
ON
1 2 3 4 5 6 7 8
ID numbers of each camera are set up using binary numbers.
See the examples shown below:
Switch
1
2
3
4
5
6
7
8
ID Value
1
2
4
8
16
32
64
128
ex) ID=5
On
off
On
off
off
off
off
off
ex) ID=10
off
On off On
off
off
off
off
The camera ID range is 1~255. The Camera ID must not be 0.
Factory default of Camera ID is 1.
Match the camera ID with Cam ID setting of your DVR or Controller
to control the camera.