VS-570-HDSDI 2.0 Megapixel Speed Dome User Manual ver.1.0 v1.
VS-570-HDSDI User Manual Safety Precaution We appreciate your purchasing VS-570-HDSDI. Before installing the product, please read the following with care. Make sure to turn off the power before installing VS-570-HDSDI. Do not install under the direct sunlight or in dusty areas. Make sure to use the product within the temperature and humidity specified in the specification. Do not operate the product in the presence of vibrations or strong magnetic fields.
VS-570-HDSDI User Manual Table of Content 1. Introduction ................................................................................................................................. 4 About this manual ..................................................................................................................... 4 Features ................................................................................................................................... 4 Product and Accessories ...............
VS-570-HDSDI User Manual 1. Introduction About this manual This User Manual provides information on operating and managing the premium network camera, VS-570HDSDI. The Manual includes instructions of installation, operation and configuration of VS-570-HDSDI troubleshooting tips. Features VS-570-HDSDI is a 2.0M PTZ network-based camera with remote live monitoring, audio monitoring and control via an IP network such as LAN, ADSL/VDSL, and Wireless LAN.
VS-570-HDSDI User Manual Serial Data • RS-485 support: • Data pass-through mode: Serial data communication between VS-570-HDSDI and Decoder. Sensor and Alarm • Supports direct connections of external sensor and alarm devices. • Event Alarm notification. • 2 alarm sensor Inputs and 2 alarm Output relays are available. • If an external sensor is activated, camera can be set to move to the corresponding Preset position.
VS-570-HDSDI User Manual PTZ(Pan/Tilt/Zoom) Control • With RS-485 communication, a maximum of 255 cameras can be controlled at the same time. • Pelco-D or Pelco-P protocol can be selected as a control protocol in the current version of firmware. Easy Installation and Perfect Outdoor Environment Compatibility • Fans and heaters are built into the camera enclosure for both hot and cold temperature environments. Advanced mechanical design protects the camera from damaging water and dust.
VS-570-HDSDI User Manual Product and Accessories Main body & Dome Cover Accessories Main Cable Cross LAN Cable Wrench Driver 2EA of BNC Audio Cable CD Note: Mount Brackets are optional. Wall Mount Bracket [Screws : Torx Screw M418, Hex Lag #1450] 2.
VS-570-HDSDI User Manual Part Names and Functions ① • Dome Cover To protect the dome cover from scratches or dust Do Not Remove the protective vinyl from the dome before completing the installation process. • DIP Switch Sets up camera ID and protocol. • Drop Prevention Spring This prevents the camera from dropping during installation and maintenance. After installing the Bracket, please connect the spring to the drop prevention hook of main body as shown in picture.
VS-570-HDSDI User Manual System Connections VS-570-HDSDI IP Cameras can be connected in either 1 to 1 connection where one VS-570-HDSDI is connected to one PC client or a decoder system or, 1 to many connections where one VS-570HDSDI can be connected to several PCs and decoder systems. The VS-101 video server can work as a video decoder which takes the data from a video server or IP camera, decodes and outputs analog or digital video, HDMI and HDSDI.
VS-570-HDSDI User Manual 1:N Connection . Site Remote Center or or or In this configuration, a site can be monitored from many remote central locations. Although up to 64 PCs or decoders can be connected to one VS-570-HDSDI, in the real network environment, network bandwidth can limit the maximum connections. Functionally, the central monitoring system (CMS) software provided can replace the decoder.
VS-570-HDSDI User Manual CMS (Central Monitoring System) Site Site Remote Center Remote Center (Decoder) CMS CMS (Central Monitoring System) is a Window-based remote monitoring program used to monitor or control video, audio, and events in real time from several IP cameras or video servers. Please refer to the CMS User Manual for more detail. 2.
VS-570-HDSDI User Manual 2. Installation DIP Switch Setup When you control the camera through RS-485, before installation, you should set the DIP switches to configure the camera ID, communication protocol. Camera ID setup ON ON ID numbers of each camera are set up using binary numbers. See the examples shown below: 1 2 3 4 5 6 7 8 2.
VS-570-HDSDI User Manual Communication Protocol Setup ON ON 1 Select the appropriate Protocol with DIP switch combination. Switch State 2 3 4 S0 (Pin 1) S1 (Pin 2) S2 (Pin 3) Protocol/Baud rate OFF OFF OFF PELCO-D, 2400 bps ON OFF OFF PELCO-D, 9600 bps OFF ON OFF PELCO-P, 4800 bps ON ON OFF PELCO-P, 9600 bps Otherwise Reserved If you want to control using a DVR or P/T controller, their protocol must be identical to the camera otherwise, you can not control the camera.
VS-570-HDSDI User Manual Camera Installation using Brackets Installation using a Ceiling Mount Bracket (not supplied) ① Remove the ceiling tile from the ceiling and cut a hole whose diameter is 30~40mm on the ceiling tile to pass the wire(s) and cable(s) through to the upside of the ceiling. Then prepare the ceiling mount bracket. Pull the wire(s) for the system as below. ② Hook up the “Drop Prevention Spring” on main body to prevent the camera from unexpected drops.
. VS-570-HDSDI User Manual Installation using the Wall Mount Bracket ① Make a hole whose diameter is 30~40mm on the mounting surface to pass the wire(s) and cable(s) through the mounting surface. ② Hook up the “Drop Prevention Spring” on main body to prevent the camera from unexpected drops. Pull the wire(s) and cable(s) for the system as below. Prepare the wall mount bracket by Pulling the wire(s) and cable(s) for the system as below. Attach the wall mount bracket to the mounting surface.
VS-570-HDSDI User Manual Wiring/Cabling & Connecting Port Description Main Cable Port Pin Number (RJ45) Connector / Wire Color Signal 1 Black RS485 + 2 Brown RS485 3 Red DC 12V 4 Orange Ground 5 Yellow OUT COM (Relay Output Common) 6 Green OUT 2 (Relay Output 2) 7 Blue OUT 1 (Relay Output 1) 8 Violet IN COM (Sensor Input Common) 9 Gray IN 1 (Sensor Input 1) 10 White IN 2 (Sensor Input 2) Port Pin Number Connector/ Wire Color Signal 1 RCA (Yellow) Audio IN Audio
VS-570-HDSDI User Manual Connecting Power 1. Carefully check the voltage and current capacity of the rated power. The rated power is indicated in the back of main unit. 2. After confirming the voltage, connect the power adaptor to the AC power source then connect the 12V DC connector to the system . For the DC input models, be careful with the polarity of the DC power. The system will be permanently damaged if connected to reverse polarity power supplies.
VS-570-HDSDI User Manual Connecting Serial Port (RS-485 Communication) For PTZ control, connect the cable(s) to your keyboard or DVR. To connect multiple cameras to a single controller, the RS-485 communication should be connected in parallel as shown below. If you are connecting a single camera to a controller, you must terminate the camera. When connecting more than one camera to a single controller, terminate the last camera on the communication line.
VS-570-HDSDI User Manual Relay Output Internal AC or DC OUT COM OUT 1 LOAD OUT 2 LOAD Maximum allowable electrical load of relay is shown bellow table. Drive Power DC Power AC Power Max. Load Max DC 24V, 1A Max AC 125V, 0.5A Check if it works Once the power is supplied to the camera, it will start booting. The system will boot up to an operating mode after approximately 40-60 seconds. The green LED on the Ethernet port will flash indicating the system is ready.
VS-570-HDSDI User Manual 3. System Operation Remote Video Monitoring There are two ways to monitor video when the center system and VS-570-HDSDI are connected. In order for proper operation, an IP address must be set accordingly. Please refer to True Manager in Chapter 3 or Remote Setting in Chapter 4 for further details. Default ID : admin Default Password : 1234 . Video Monitoring using Internet Explorer Open Internet Explorer and enter VS-570-HDSDI‟s IP address.
VS-570-HDSDI User Manual Video Selection Select the Video stream to be viewed: Primary or Secondary. The VS-570-HDSDI is capable of dual streaming; primary streaming and secondary streaming. Video will be displayed according to the resolution set in the video configuration. If dual streaming (“Use Dual Encode” Menu on the Video page) is not activated, the secondary video will not be available. Screen Size Adjust the Screen size.
VS-570-HDSDI User Manual Select Preset Set the preset position, move to the specific preset position or clear the preset position. - Go to: Moves to the selected preset entry if the preset entry is set. - Set: Sets the current position to the selected preset entry. - Clear: Deletes the selected preset entry. Select List Operate the selected Pattern or Swing or Group.
VS-570-HDSDI User Manual Video Monitoring with Decoder System Once the VS-570-HDSDI‟s IP address is set in the remote IP address section of the decoder, the decoder system will connect to VS-570-HDSDI and start receiving the video images. Normally, a monitor connected to the decoder will display video images. Initialization of IP address If a system IP address is lost, the system can be reset to the system default IP address using the reset button in the rear of the system. 1.
VS-570-HDSDI User Manual 4. Remote Configuration Using Web Brower Remote setting is available by using the web browser. Enter the IP address of a VS-570-HDSDI, a live view screen appears as below. Press the Setup button located in the upper right area of the monitoring screen to go to the server setup. To change Remote Settings, the user must be authorized higher than manager level.
VS-570-HDSDI User Manual System Configuration 2.
VS-570-HDSDI User Manual General System ID Enter the System ID that will be used as the camera title. The set System ID will be displayed with video image on the web browser. The System ID is also transferred to remote software, such as CMS, and displayed on it. Language Select the language to be used for web-based configuration. Firmware Firmware version Displays the current firmware version. Board ID Display the Network board ID of VS-570-HDSDI recognized by system.
VS-570-HDSDI User Manual Time Start Time This is the date and time when the camera was last booted. Current Time This is the current date & time. Enter a new date and time and press the Set Current Time button to update. Time Format This allows you to change the time format. Selectable time formats are as follows: - YYYY/MM/DD hh:mm:ss (Ex. 2010- 4-11 18:18:42) - DD/MM/YYYY hh:mm:ss (Ex.11- 4-2010 18:18:42) - MM/DD/YYYY hh:mm:ss (Ex.
VS-570-HDSDI User Manual Factory Reset This changes the Current IP Address of VS-570-HDSDI to default IP Address: 192.168.10.100. The System log and user registrations are also cleared. All other setting values will remain. Note that the Password will not be changed by the Factory Reset for the security purpose. Please contact Marshall Electronics Technical Support if you forget your password. 2.
VS-570-HDSDI User Manual Video Configuration 2.
VS-570-HDSDI User Manual Encode Enable Preview 1. Select ON to display video on the monitor that is connected to the composite or HD-SDI video port. 2. Select the Output format accordingly in the end of the Video page. Note that when Enable Preview is ON, dual streaming is not available. When the video is transmitted directly to the monitor through the BNC cable, the video signal bypasses the network and encoding. Resolution Select the video encoding resolution required.
VS-570-HDSDI User Manual Quality Select the required Video quality. Eight levels of quality are available. Quality mode (VBR encoding) adjusts the bit rate according to the image complexity, using higher bandwidth for increased activity in the video and lower bandwidth for decreased activity. For active video content such as sports, or when network bandwidth is limited, It is reccomended that CBR or Bit Rate encoding be used. Bit rate Set the bit rate value between 32 ~ 8000kbps.
VS-570-HDSDI User Manual Dual Encode Use Dual Encode 1. Select the Off button on the Enable Preview to enable to use Dual Encode. 2. Select the ON button to enable to use Dual Encoding. The secondary video can be viewed on Live View window by selecting Secondary on Video selection. Dual Compression Algorithm Select H.264 or MJPEG for the secondary streaming. Maximum resolution is 1280 x 720 and 9 steps of resolution are available.
VS-570-HDSDI User Manual Sensitivity Sensitivity selects the amount of movement required to trigger (detect) a motion event. The value determines the sensitivity of the motion detection within a block. The lower the number the more sensitive to movement. Select from 0 to 10. Information Display System ID and/or server time can be display over the video window in Internet Explorer. Each item can be turned on or off separately, and the position also can be configured.
VS-570-HDSDI User Manual Audio Configuration Algorithm Algorithm Select the audio algorithm: G.711 or AAC. Bitrate Select the Bitrate to be 64kbps or 128kbps when AAC is selected. The sampling rate is fixed to 32KHz when G7.11 is selected. Note that when VS-570-HDSDI is connected to a decoder, the decoder‟s audio algorithm MUST be set identically to transmit audio and video properly.
VS-570-HDSDI User Manual Network Configuration 2.
VS-570-HDSDI User Manual Local IP mode Select the IP mode: Fixed IP or DHCP (Dynamic Host Configuration Protocol) Depending on the mode selected, configuration items will appear as follows: IP Mode Selection Local IP Fixed IP Local Fixed IP address Gateway IP address Gateway Local Subnet DHCP Description Subnet mask N/A ☞ Please request IP address information from your ISP provider or network manager. DNS Obtain DNS server address automatically.
VS-570-HDSDI User Manual HTTP Port Enter the HTTP port used for web-based connection. RTSP Port Enter the RTSP port used for RTSP-based connection. The default RTSP port is 554. RTSP (Real Time Streaming Protocol) is a standard for connected client(s) to control streaming data over the World Wide Web. Authentication RTSP Authentication If the RTSP Authentication set to ON, the user must enter correct User ID and Password when any RTSP client is connected.
VS-570-HDSDI User Manual SNMP The VS-570-HDSDI can be used as an SNMP agent. It is compatible to both SNMPv1 and SNMPvec. Settings for using SNMP (Simple Network Management Protocol) are as follows: SNMP Listen Port: This port is used for connecting external devices when the system operates as an SNMP client. SNMP is not used when setting a 0 value. SNMP Trap Destination IP: Set the SNMP Trap Destination IP. SNMP Trap Destination Port: Set the SNMP Trap Destination Port.
VS-570-HDSDI User Manual Check IP Disable: If “Check IP Disable” is selected, the IP Server will skip to check its own IP. In Fixed IP mode, the set IP will be registered on the DDNS server. In DHCP mode, the allotted IP will be registered on the DDNS server. Normally Check IP Disable can be unchecked.
VS-570-HDSDI User Manual Serial Configuration 2.
VS-570-HDSDI User Manual Serial Port Configuration Serial Port Information RS-485 in VS-570-HDSDI support one RS-485 serial port. The camera‟s serial port information is displayed automatically once the camera reboots after the DIP switch setup of the camera. PTZ Type & ID: PTZ Type & ID are displayed automatically once the camera reboots after DIP switch setup. The default PTZ Type and ID is Pelco-D and 2400bps. Sensor Type There are two sensor input ports on VS-570-HDSDI.
VS-570-HDSDI User Manual Event Configuration 2.
VS-570-HDSDI User Manual The VS-570-HDSDI has two sensor ports and two alarm ports. When a decoder instead of a PC client is connected to a VS-570-HDSDI, one system becomes a Local system and the other a Remote system. Generally a system which is being used by the user is called the Local system. Then, actions for events can be configured for events from the remote system as well as for local system.
VS-570-HDSDI User Manual E-mail Notification Specifies the information required to send event information, when E-mail is selected as an event action. - Server Address: Enter an address of a mail (SMTP) server. - Port: Specify a port for SMTP operation. Port 25 is the default port in SMTP operation. If a different port is configured in the SMTP server, this port needs to be changed accordingly. - Sender Address: Enter an account registered in the SMTP server.
VS-570-HDSDI User Manual PTZ Configuration 2.
VS-570-HDSDI User Manual PTZ Control PTZ using the PTZ controller Preset A Maximum 128 positions can be stored as Preset positions. 1. Move the position to be set. 2. Select one of the entries of Preset from the list. 3. Press Set button. 4. Enter the preset name to be used and press Save Label button. 5. Press Go to button to move to the present position.
VS-570-HDSDI User Manual Swing By using Swing function, you can make camera to move between 2 Preset positions repeatedly. When swing function runs, camera moves from the preset assigned as the 1st point to the preset assigned as the 2nd point in CW(Clockwise) direction. Then camera moves from the preset assigned as the 2nd point to the preset assigned as the 1st point in CCW(Counterclockwise) direction.
VS-570-HDSDI User Manual Ex) Group-1 Swing-1 Repeat 2 Preset-1 5 Speed 3 Pattern-1 10 Repeat100 3 Live View Page Select List-1 and Press Group to playback the Group-1 program. 2.
VS-570-HDSDI User Manual Record Configuration This page is not available from the VS-570-HDSDI When using the VS-570-HDSDI the Record page is not available. 2.
VS-570-HDSDI User Manual User Configuration User List Users can be registered and the privilege level of each user can be specified. User configuration is allowed only by the Admin user. A maximum of 16 users can be registered and each user can have one of four privileges: Privilege Admin Manager Allowed Operations All operations Remarks User ID = admin All operations except for user configuration User Live viewing and PTZ control Guest Live viewing only Add User Press the Add button.
VS-570-HDSDI User Manual Delete User Select the User to be deleted and press the Delete button. Change Password Press Modify Password button. The following window will appear: Enter the current password and then set a new password. Modify Privilege Level Press the Modify Privilege button to change the User privilege level. It is not allowed to change the privilege level of the admin user.
VS-570-HDSDI User Manual Camera Configuration 2.
VS-570-HDSDI User Manual Day & Night The camera delivers color images during the day. As light diminishes below a certain level, the camera can automatically switch to night mode (Black & White mode) to maintain good image quality. Day & Night function can be selectable according to the environment. - Auto : Automatically switches to Day (Color) or Night (B&W) according to light using ICR (Infrared Cut filter Removable). - Day (Color): Delivers a color image regardless of light.
VS-570-HDSDI User Manual ETC Digital Zoom Determine the Digital zoom (12x) supported by the camera zoon lens. x10 Optical zoom and x12 Digital zoom lens (f=5.1 ~ 5.1mm) is built-in VS-570-HDSDI. Aperture Level Set Aperture Level from 0 to 15. Aperture control is a function which adjusts the enhancement of the edges of objects in the picture. There are 16 levels of adjustment, starting from “no enhancement.” When shooting text, this control may help by making the text sharper.