Specifications

THE SHALLECK COLLABORATIVE SANTA ROSA CITY COUNCIL
AV SYSTEMS UPGRADE
April 6, 2012 27 41 16  10 AV SYSTEMS
100% CD
F. Shop Drawings:
1. Submit fullsize (minimum 30” x 42”) scaled shop drawings that show the following:
a. Installation requirements and mounting conditions.
b. For loudspeaker clusters, or any device suspended from above: Provide stamped
structural drawings by a structural engineer licensed in the State California.
c. Full system riser diagram(s) illustrating interconnection of system components, wiring
requirements, back box sizes and any special installation considerations.
d. Block diagrams, showing equipment interconnection.
e. Internal DSP programming (may be submitted as software file, or in flowchart form on
paper)
f. Equipment rack and patchpanel drawings.
g. Fullscale drawings of custom plates.
h. Run sheets or field wiring drawings.
i. Equipment modification drawings, including statement of purpose for modification
and agreement to provide full manufacturer warranty, if modifications cause a voided
warranty.
j. Final schematic drawings of any custom circuitry.
k. Detailed equipment list, including quantity, manufacturer and model.
l. Detailed product drawings, as applicable to the project.
m. Copies of contract drawings will not be accepted as shop drawings, and will be
returned without review.
2. AV Control System Touchpanels:
a. Provide an electronic file for approval of working touchpanel files. File shall be in a
format that both consultant and The Owner can use on any windowsbased computer
(with required software installation.)
b. Provide any required viewing software.
c. Touchpanel design subcontractor is responsible for design of touchpanel layouts, but
shall be subject to consultant and Owner’s Representative approval.
3. Acceptance of any submitted data or shop drawings for material, equipment, apparatus,
devices, arrangement and layout shall not relieve contractor from responsibility of
furnishing same of proper dimensions and weight, capacities, sizes, quantity, and
installation details to perform efficiently the requirements and intents of the systems
design. Such acceptance shall not relieve the contractor from responsibility for error,
omissions or inadequacies of any sort on submitted data or shop drawings.
G. Product Data:
1. Submit a detailed equipment list, including manufacturer, model number, description and
quantity for each item.
2. Do not submit equipment cut sheets, except for custom or nonstandard devices.
H. Samples:
1. Submit samples for review. Samples may include, but are not limited to:
a. Connector, panel and cable assemblies
b. Panel finish samples
c. Custom switch, button or similar assemblies