Specifications
28
Navigator
The Network Control page’s Navigator allows you to scan your network for any other Marshall Electronics Web Enabled MD
monitors. From the navigator, you can find and sort all monitors by their Host Name, IP Address or Model number. You can also
access each monitor’s Network Control page.
Press the Scan Network button once to scan your network for other MD monitors. The navigator will not detect any monitors
added to the network if the scan was performed prior to their installation.
The information field at the bottom will indicate the Host Name, IP Address and model number of the origin of the Navigator pop
up page. It will also give a count of how many monitors have been found on the network.
Info Tab
■
System
This shows the System firmware version of your monitor.
■
Power Module
This shows the Power Module firmware version of your monitor.
■
Keypad
This shows the Keypad firmware version if your monitor has a Keypad separate from the main system board.
■
Slot
This field determines the type of module present on the system as well as its firmware version. If there is no module
installed, the text will read “No Module v0.00.”
5
Installation and Initial Setup
■ Unpacking
Carefully unpack the V-MD902 monitor and verify that the following items are included:
• V-MD902 Monitor
• V-PS12-5V-1 Power Supply
• Operating Instructions
Inspect the unit for any physical damage that may have occurred during shipping. Should there be any damage, immediately
contact Marshall Electronics at (800) 800-6608. If you are not located within the continental United States, call +1 (310) 333-
0606.
■ Installation
The V-MD902 can be mounted in any standard EIA 19” equipment rack. The attached rack ears can be angled to provide the user
control over the viewing angle. Adequate ventilation is required when installed to prevent possible damage to the monitor’s
internal components. Please see the Dimensions section for more information.
■ Connections, Power-On and Initial Setup
Plug the power supply into an AC power source (100-240 V @ 50/60 Hz). Attach the Power connector to the back of the monitor.
Connect the required cables for video signal input and output. (Power must be applied to the V-MD902 for the active loop-
though output to be activated.) The monitor defaults to ‘ON’ when power is supplied. Video will automatically be detected and
displayed on the screen.