Operating instructions

13
H/V Delay
Use this setting to enable one of three delay modes (H & V Delay, V Delay, H Delay):
In H & V Delay mode, both horizontal sync and vertical sync are delayed, resulting in both horizontal and vertical
blanking periods being shown on the screen.
In V Delay mode, vertical sync is delayed so that the vertical blanking period is displayed on screen.
In H Delay mode, horizontal sync is delayed so that the horizontal blanking period is displayed on the screen.
Underscan
Use this setting to enable or disable Underscan mode:
When Underscan is OFF, the active portion of the video signal is displayed on the screen, with 0% overscan.
When Underscan is ON, the image size is slightly reduced. This allows the user to clearly view the edges of the
active video area.
NTSC Black Level
Set the NTSC Black Level according to the type of NTSC composite video input:
7.5 IRE: Use this setting for standard NTSC-M signals which use a 7.5 IRE setup (black level).
0 IRE: Use this setting for NTSC-J signals which have no setup, or a black level of 0 IRE.
Note: This setting is disabled for PAL composite input and all component/HDMI formats.