Manual

Page 8 of 39
Features
Select Color Temperature and Gamma Mode
Color temperature presets may be selected between D65 or D93 as well as user-definable
settings. Gamma settings are adjustable from 1.0 to 3.0 in 0.1 steps. The standard setting is 2.2.
Flexible Screen Markers
A variety of screen markers in 4:3, 16:9, and full screen modes allow accurate monitoring of the
different aspect ratios used in broadcast environments.
User-Assignable Function Buttons
Seven user-assignable function buttons and one rotary encoder on the front panel allow quick
access to numerous settings and features including the video Inputs, Waveform, Vectorscope,
Audio Bars, Aspect Ratio, Screen Markers, Monochrome Mode, H/V Delay Mode, and more.
AUDIO Jacks
There are three 3.5mm AUDIO Jacks (one on the front panel for headphones and two on rear
panel. One for an auxiliary audio input and one output to feed an external amplifier). It is possible
to utilize both the front panel headphone connector and rear panel speaker connector
simultaneously with individual volume controls. The Aux audio input may be selected as a source
when the video input is set to SDI.
Installation and Initial Setup
Unpacking
Carefully unpack the OR-2410 monitor and verify that the following items are included:
• OR-2410 Monitor with attached desk stand
• Power cord.
• Operating Instructions (This Manual)
Inspect the unit for any physical damage that may have occurred during shipping. Should there
be any damage, immediately call Marshall Electronics Customer Service at (800) 800-6608. If
you are not located within the continental United States, call +1 (310) 333-0606.
Mounting
The OR-2410 is designed as a tabletop production monitor. It comes complete with tabletop
stand and integrated carry handles.
Connections and Power-On
The OR-2410 can receive power from a standard AC power outlet (100~220VAC) or a 24VDC 4-
pin XLR power supply.
Connect the required cables for video signal input and output (power must be applied to the OR-
2410 for the active loop-outputs to be activated). All BNC connectors are rated at 75.