Manual
Page 33 of 39
An error count of more than 1 could be considered as abnormal. There is no particular scale to
the number of errors counted. The max number of errors displayed is 9999. For example assume
that there is a problem with a source and it is outputting a SDI signal with invalid CRC for each
line. The Orchid Error counter will result in a count of 9999 within 9 frames (150ms). However, if
the source is not bad and the Error counter occasionally counts up these are mostly caused by
poor connections or bad SDI cables.