Operating instructions
7
Monitor Rear
VESA Mounts
VESA standard 75 mm and 200 mm hole
patterns are provided to accommodate a variety
of custom mounting options.
RS-422 / 485 Serial Interface
The RS-422/485 ports are used to remotely
control the 3D-241-HDSDI and IMD/Tally
functions using a variety of industry standard
protocols. Only one connection to either port is
needed to control the monitor. The second port
can be used to loop multiple IMD capable
monitors in the same bus. This connector is also
used for field firmware upgrades.
Service Connector
DO NOT USE. This is for factory use only.
Connecting any device to this port may damage
the unit.
Tally
The OSD tally can be activated via the HD-15
connector by connecting the corresponding pin to
ground. A variety of external devices can be
used to perform the contact closure. No
additional power should be supplied to the HD-15
port.
Power Input
Connect the 24 VDC output to the XLR power
input connector. Power can be supplied from the
included power supply or from a variety of DC
sources supplying at least 6.0 Amps at 24 Volts.
Important: If using a power source other than
the included power supply, be sure that the
polarity of the DC output is correct.
Pin 1: Ground
Pin 2: N/C
Pin 3: N/C
Pin 4: +24 VDC
HDSDI Inputs and Output
Connector
The 3D-241-HDSDI has four HDSDI inputs and
four active loop-through outputs.
Inputs are arranged as:
A – Left and Right
B – Left and Right
DVI-I Input Connector
Integrated DVI Digital and Analog input. Includes
EDID and HDCP for connection to Computers,
DVD Players, Rasterizers, etc.
* NOTE* DVI input does NOT support Consumer
3D Formats (HDMI 1.4)