Step 34: Cable ties and final inspection.
Your chassis should now be fully assembled and ready for the testing and powering up procedures
documented in the TESTING section. One final touch that makes for a clean amp build is to bundle
wires together using cable ties. One cable tie every inch or so gives good results.
Note: do not use a cable ties to bundle the output transformer primary and secondary wires as this can
cause cross talk between them, resulting in oscillation. Same for the ORANGE and GREEN output tube
grid wires.
Take some time to look over your work, double check any steps that you may feel uncertain about and
verify each solder connection. When you are satisfied, move on and begin the testing process.