TD2100 Manual Gummed Tape Dispenser Owner’s Manual 1 40974 Rev.
A wall-socket must be close to the product and readily accessible. The overall system is protected against overload by the branch circuit protection in accordance with the current edition of the NEC or CEC Table of Contents Introduction ..................................................................................................................................... 3 Warranty Information .....................................................................................................................
Introduction Congratulations on the purchase of your new MARSH TD2100 Gummed Tape Dispenser from MSSC, LLC. We are confident you will be very pleased with the operation and performance of this durable, quality built machine for many years to come. The TD2100 Gummed Tape Dispenser Owner’s Manual provides the necessary information about the operation and maintenance of your new tape dispenser.
Warranty Information MSSC, LLC warrants that your selling distributor will repair, replace, or adjust components found to be defective in factory materials or workmanship for a period of 18 months. Your Marsh distributor will provide free service for ninety (90) days from the beginning of the warranty period. The warranty period begins on the original installation date as indicated on your on-line warranty registration. Conditions of warranty: 1.
Specifications Shipping Weight: 31 pounds (14.1 kg) Water Bottle Capacity: 70 ounces (2070 ml) Tape: Dry gummed tape – paper or reinforced – between 1 to 3 inches (25.4 to 76.2 mm) wide, up to 1000 feet (304.8 m) long and 9 inches (228.6 mm) max roll diameter For Units with Heater: Electrical Requirements: Power Cord Length: 115 volts AC or 220 volts AC 50/60 Hz 4 amps at 115 volts 2 amps at 220 volts 7 feet (2.3 m) Dimensions: 10.5 in 26.6 cm 13.7 in 34.8 cm 18.9 in 48.
Setup Instructions Pressure Plate Top Roller Tape Guide Turnbuckle Tape Guide Pinch Roller Lighted Power Switch (Units with Heater Only) Top Cover Length Scale Mechanical Stop Figure 2 – Loading Tape Loading Tape – Figure 2 & 3 1. Open the top cover of the machine. 2. Adjust the tape guides, with the tape guide turnbuckle, wide enough to get the tape between them. 3. Place the roll of tape into the machine. 4.
Pinch Roller Shaft Pinch Roller Pressure Plate Top Roller 1000 ft. Roll of Tape Cutter Assembly Gummed Side Out Tape Figure 3 – Tape Routing Water Bottle Duck bill Valve Tape Weight Water Bottle Brackets Brush Tank Post Figure 4 – Filling the Water Bottle, Adjusting the Brush Tank Water Level, Adjusting the Tape Weight 7 40974 Rev.
Filling the Water Bottle – Figure 4 1. Remove the water bottle from the machine. 2. Remove the duckbill valve from the water bottle. 3. Fill the water bottle with water. 4. Place the duckbill valve back into the water bottle. 5. Place the water bottle back onto the machine; verify that the post in the brush tank is inserted through the duckbill valve. Low Medium High Water Bottle Bracket Figure 5 – Adjustable Water Level Positions Adjusting the Brush Tank Water Level – Figure 4 & 5 1.
Operating Instructions Once the machine has been properly setup for use, pull the operating handle to the desired length that is on the scale and release the handle, when the handle returns to the resting position the tape will be cut. The mechanical stop is provided on the side of the machine (Figure 2) to be used if a known length will be used repeatedly.
Water Tank Shelf Cutter Guard Cleaning Gaps Pressure Tape Channel Plate Weighted Brush Tank Cover Cutter Assembly Figure 6 – Cleaning the Cutter Assembly, Cleaning the Tape Path Cleaning the Cutter Assembly – Figure 6 1. For units with heater, turn the power switch to the off position and unplug the power cord. 2. Open top cover. 3. Remove pressure plate. 4. Remove the tape from the tape path. 5. Using minimal amount of a non-flammable lubricant (MG Chemicals Super Penetrating Lubricant [www.
Cleaning the Tape Path – Figure 6 1. For units with heater, turn the power switch to the off position and unplug the power cord. 2. Open the top cover. 3. Remove pressure plate. 4. Remove tape from tape path. 5. Using compressed air remove all debris form the tape path. 6. Using a moist cloth wipe down all sheet metal parts within tape path (tape channel, pressure plate, weighted brush tank cover, and water tank holder) to remove the gum adhesive buildup. 7.
Troubleshooting This section describes potential problems you may encounter while working with your TD2100 tape machine and outlines possible causes and solutions for these problems. To avoid problem situations, be sure to follow the procedures in the setup and maintenance sections. For units with heater, before performing any repair procedures be sure that the power switch is in the off position and is disconnected from the power source. The tape is jamming, tearing, or won’t feed.
Parts List Item Number 1 2 3 4 5 6 7 8 9 10 11 12a 12b 13 14 Part Number RP40401 RP41257 RP40505 RP40404 RP33460 RP40403 RP40407 RP40405 RP40517 RP41325 RP41302 RP41260 RP41262 RP40311 RP40310 Description Water Bottle Handle Pressure Plate Rear Water Bottle Bracket with Screw Duck Bill Valve Front Water Bottle Bracket Brush Brush Tank Tape Weight with Screw Cutter Guard with Screws Hole Plug Inch Meashuring Strip Metric Measuring Strip Top Cover Hinge with Screw (Qty 2) Top Cover 13 40974 Rev.