V
ertical Outdoor
Condenser Fan Motors
Shaft-Up/Down
GE up/down outdoor condenser fan
motors are designed for either
vertical shaft-up or shaft-down
applications. Shell and end shields
are enclosed for weather
protection. A weep hole is
provided in each end shield to
allow condensate to drain. A
plastic plug is provided to seal the
weep hole in the end shield
exposed to the weather. All of
these motors are suitable for air
conditioning or heat pump
applications. All feature reversible
rotation, 208-230 volts, six inch
shaft length and extended thru
bolts extending from both ends.
Specifications:
60 Hertz
Single phase
Overload protected
Fan duty, continuous, air over
26 inch leads
Totally enclosed, non-ventilated
Class B insulation
Features:
Up/down design
Thru bolt or band mounting
All angle sleeve bearings
Water slinger on shaft
Serrated end cap on shaft end only
For air conditioning or heat pumps
Full six inch shaft length with two full flats at 90°
Reversible rotation
48 inch leads
For accessories see pages M-50 – M-54
Condenser Fan Motors
MARS Motors
M44
GE by RBC
GENTEQ
M–44
®
marsdelivers.com
Toll Free (800) 445-4155 Fax (631) 348-7160
www.marsdelivers.com
Vertical Outdoor
Condenser Fan Motors
Shaft-Up/Down
Ball Bearing
GE up/down outdoor condenser
fan motors are designed for
either vertical shaft-up or shaft-
down applications. Shell and end
shields are enclosed for weather
protection. A weep hole is
provided in each end shield to
allow condensate to drain. A
plastic plug is provided to seal
the weep hole in the end shield
exposed to the weather. All of
these motors are suitable for air
conditioning or heat pump
applications. All feature reversible
rotation, 208-230 volts, six inch shaft
length and extended thru bolts
extending from both ends.
Features:
Thru bolt or band mounting
All angle mounting
Water slinger on shaft
Serrated end cap on shaft end only
For air conditioning or heat pumps
Full six inch shaft length with two
full flats at 90°
Reversible rotation
For accessories see pages M-50 – M-54
Rheem mtg. holes
(mtg. hardware included)
Specifications:
60 Hertz
Single phase
Overload protected
Fan duty, continuous, air over
48 inch leads
Totally enclosed, non-ventilated
Class B insulation
* Heat Shield
Reversible Rotation
(1) Low speed approximately 300 RPM less than high speed depending on fan load
(2) Both end shields flat, no serrated end cap (3) 26” leads
MARS
NO.
GE NO.
5KCP39
HP VOLTS AMPS RPM
(1)
CAP
REQ.
DIMENSIONS
A B C
825 RPM - Single Speed - Standard Efficiency - 8 Pole
03201
(3)
EGL248S 1/10 208-230 0.80 825 5/370 6.0 4.30 1/2
03202* DFBA81S 1/8 208-230 0.85 825 5/370 6.0 4.30 1/2
03203* HFBA79S 1/6 208-230 0.90 825 5/370 6.0 4.30 1/2
03204* JFBA83 1/4 208-230 1.3 825 7.5/370 6.0 5.03 1/2
03205* NFBA82S 1/3 208-230 1.8 825 10/370 6.0 5.80 1/2
1075 RPM - Single Speed - Standard Efficiency - 6 Pole
03726 * HGU722S 1/6 208-230 1.0 1075 5/370 6.5 3.98 1/2
03732
(2)
* GGU714S 1/4 208-230 1.7 1075 5/370 6.0 4.23 1/2
03733
(2)
* LGU715S 1/3 208-230 2.6 1075 7.5/370 6.0 4.48 1/2
03734
(2)
* RGU718S 1/2 208-230 3.0 1075 10/370 6.0 5.23 1/2
03735
(2)
* SGU717S 3/4 208-230 4.1 1075 10/370 6.0 5.98 1/2
* Heat Shield
Reversible Rotation
MARS
NO.
GE NO.
5KCP39
HP VOLTS AMPS RPM
CAP
REQ
DIMENSIONS
A B C
1075 RPM - Single Speed - Standard Efficiency - 6 Pole
03727 DGS375S 1/6 208-230 1.0 1075 5/370 6.0 4.71 1/2
03727HS* DGY797S 1/6 208-230 1.0 1075 5/370 6.0 4.71 1/2
03728 FGM599S 1/4 208-230 1.8 1075 5/370 6.0 4.25 1/2
03728HS* GGY769S 1/4 208-230 1.7 1075 5/370 6.0 4.25 1/2
03730 PGS618S 1/2 208-230 3.5 1075 10/370 6.0 6.50 1/2
03730HS* RGY799S 1/2 208-230 3.0 1075 10/370 6.0 6.50 1/2
5
1
2 inch dia.
5
1