Brochure
 à Installation heights 
Flying insect control up to 7’ 
Temperature control up to 8’
 à Variable speed motor and switch
 à Slim aesthetic design 
 à Heat options available–electric, steam, hot water
 à Standard color– Obsidian Black
 à Installation heights 
PH10 Flying insect control up to 8’ 
PH10 Temperature control 10’ to 12’ 
PH12 Flying insect control up to 10’ 
PH12 Temperature control 12’ to 14’
 à Recessed mounted in ceiling for 
invisible coverage
 à Utilized in premium design projects
 à Durable aluminum construction
 à Heat options available– electric, steam, 
hot water
 à Standard color– Pearl White
 à AMCA rated models
 à Installation heights 
Flying insect control up to 8’ 
Temperature control 10’ to 12’
 à Proprietary motor fan assembly for easy 
installation & maintenance
 à Low profile design
 à Heat options available– electric, steam, hot water
 à Standard color– Obsidian Black
 à AMCA rated models
LoPro 2
Phantom
Standard 2
Model
Door 
Width 
Inches
Door 
Height 
Feet
Air 
Velocity 
FPM @ 
Nozzle 
(Max)
Air 
Volume 
CFM @ 
Nozzle
  115V 
208V
230V
Motor 
Horse 
Power 
dBA Sound 
Pressure 
Level 
Net Wt. 
LBS. 
Unheated
LPV2 
LPV2 25 25" 5' 1800 625 2.4 1.2/1.2 1 @ 1/6 49 20
–
LPV2 36 36" 7'-8' 1800 900 2.4 1.2/1.2 1 @ 1/6 49 32
–
LPV2 42 42" 7'-8' 1800 1050 2.4 1.2/1.2 1 @ 1/6 50 35
–
LPV2 48 48" 7'-8' 1800 1200 2.4 1.2/1.2 1 @ 1/6 52 40
–
LPV2 60 60" 7'-8' 1800 1500 2.6 1.4/1.4 1 @ 1/6 53 48
–
LPV2 72 72" 7'-8' 1800 1800 2.6 1.4/1.4 1 @ 1/6 53 58
–
LPV2 84-2 84" 7'-8' 1800 2100 4.8 2.4/2.4 2 @ 1/6 53 75
–
LPV2 96-2 96" 7'-8' 1800 2400 4.8 2.4/2.4 2 @ 1/6 53 83
–
LPV2 108-2 108" 7'-8' 1800 2700 5.0 2.6/2.6 2 @ 1/6 54 92
–
LPV2 120-2 120" 7'-8' 1800 3000 5.2 2.8/2.8 2 @ 1/6 54 102
–
LPV2 144-2 144" 7'-8' 1800 3600 5.2 2.8/2.8 2 @ 1/6 54 122
–
Model
Door 
Width 
Inches
Door 
Height 
Feet
Avg 
Velocity 
(FPM)
Volume 
(cfm)
115V 
208V
230V
208V
230V
460V 
Moto r 
Horse 
Power 
dBA 
Sound 
Pressure 
Level 
Net Wt. 
LBS. 
Unheated
STD2 
STD2 36  36" 8'-12' 2206 1379 5.1 2.5/2.5 1.8/1.6 0.8 1 @ 1/2 66 60
STD2 42 42" 8’-12’ 1945 1418 5.1 2.5/2.5 1.8/1.6 0.8 1 @ 1/2 66 65
STD2 48 48" 8’-12’ 1730 1442 5.1 2.5/2.5 1.8/1.6 0.8 1 @ 1/2 66 70
STD2 60 - 2 60" 8’-12’ 2592 2700 5.1 2.5/2.5 1.8/1.6 0.8 1 @ 1/2 66 75
–
STD2 72-2 72"
8’-12’
2206 2758 10.2 5.0/5.0 3.6/3.2 1.6 2 @ 1/2 68 120
STD2 84-2 84"
8'-12'
1945 2836 10.2 5.0/5.0 3.6/3.2 1.6 2 @ 1/2 68 125
STD2 96-2 96" 8’-12’ 1730 2884 10.2 5.0/5.0 3.6/3.2 1.6 2 @ 1/2 68 135
STD2 108-3 108" 8’-12’ 2206 4137 15.3 7.5/ 7. 5 5.4/4.8 2.4 3 @ 1/2 71 175
STD2 120-3 120" 8’-12’ 2084 4341 15.3 7.5/ 7. 5 5.4/4.8 2.4 3 @ 1/2 71 185
STD2 144-3 144" 8’-12’ 1730 4326 15.3 7. 5/ 7. 5 5.4/4.8 2.4 3 @ 1/2 73 200
Model
Door 
Width 
Inches
Door 
Height 
Feet
Avg 
Velocity 
(FPM)
Volume 
(cfm)
115V 
208V
230V
208V
230V 460V 
Moto r  
Horse 
Power 
dBA 
Sound 
Pressure 
Level 
Net  Wt.   
LBS. 
Unheated
PHANTOM 10
PH10 36 36" 8'-12' 1947 1460 5.1 2.5/2.5 1.8/1.6 0.8 1 @ 1/2 66 60
PH10 42 42" 8’-12’ 1806 1580 5.1 2.5/2.5 1.8/1.6 0.8 1 @ 1/2 66 60
PH10 48 48" 8’-12’ 1632 1632 5.1 2.5/2.5 1.8/1.6 0.8 1 @ 1/2 66 65
PH10 60-2 60" 8’-12’ 2217 2771 10.2 5.0/5.0 3.6/3.2 1.6 2 @ 1/2 68 100
–
PH10 72-2 72" 8’-12’ 1947 2920 10.2 5.0/5.0 3.6/3.2 1.6 2 @ 1/2 68 105
PH10 84-2 84"
8’-12’
1806 3160 10.2 5.0/5.0 3.6/3.2 1.6 2 @ 1/2 68 125
PH10 96-2 96"
8'-12'
1632 3264 10.2 5.0/5.0 3.6/3.2 1.6 2 @ 1/2 68 130
PH10 108-3 108" 8’-12’ 1947 4380 15.3 7. 5/ 7. 5 5.4/4.8 2.4 3 @ 1/2 71 170
PH10 120-4 120" 8’-12’ 2217 5541 20.4 10.0/10.0 7. 2 /6 .4 3.2 4 @ 1/2 73 200
–
PH10 144-4 144" 8’-12’ 1947 5840 20.4 10.0/10.0 7. 2 /6.4 3.2 4 @ 1/2 73 210
PHANTOM 12
PH12 42 42"
10'-14'
2824 2471 9.0 5.0/5.0 3.3/3.2 1.6 1 @ 1 70 90
PH12 48 48" 10’-14’ 2534 2534 9.0 5.0/5.0 3.3/3.2 1.6 1 @ 1 70 90
PH12 60 60" 10’-14’ 2207 2759 9.0 5.0/5.0 3.3/3.2 1.6 1 @ 1 70 95
–
 PH12 72-2 72"
10’-14’
3097 4646 18.0 10.0/10.0 6.6/6.4 3.2 2 @ 1 73 155
PH12 84-2 84"
10'-14'
2824 4942 18.0 10.0/10.0 6.6/6.4 3.2 2 @ 1 73 175
PH12 96-2 96"
10’-14’
2534 5068 18.0 10.0/10.0 6.6/6.4 3.2 2 @ 1 73 180
PH12 120 120" 10’-14’ 2207 5518 18.0 10.0/10.0 6.6/6.4 3.2 2 @ 1 73 190
–
PH12 144-4 144"
10’-14’
3097 9292 36.0 20.0/20.0 13.2/12.8 6.4 4 @ 1 75 270
FULL LOAD AMPS
1 Phase
FULL LOAD AMPS
1 Phase 3 Phase
FULL LOAD AMPS
1 Phase 3 Phase
Commercial, Oce, & Retail Applications
Ofce and commercial building operators want to save energy and maintain a constant internal temperature as people 
come and go. Retail shops want customers to be able to walk straight in, without having their heating and cooling costs 
skyrocket. Our LoPro, Standard, & Phantom series models can handle those jobs and provide the best performance on 
the market. In a variety of voltage, length and heating congurations, these Series are perfect for door heights up to 12’ 
and best of all, have a typical payback of 12-24 months, which is among the fastest ROI in the HVAC equipment industry. 
Ideal for customer entrances, small receiving doors, and drive-up windows. Freight allowed within the continental US.
SERIES OVERVIEW
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
ETL
LISTED
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
AMCA
•  The AMCA Certified Rating Seal applies to airflow rate, average outlet velocity, outlet velocity uniformity, 
velocity projection and power rating at free delivery only.
•  Rated data shown are only for base (unheated) units, as shown.
•  Performance data obtained from the correction factors shown herein are only an approximation and 
shall not be considered as part of the AMCA Certified Rating.
•  The AMCA Certified Rating Seal applies to airflow rate, average outlet velocity, outlet velocity 
uniformity, velocity projection and power rating at free delivery only.
•  Rated data shown are only for base (unheated) units, as shown.
•  Performance data obtained from the correction factors shown herein are only an approximation 
and shall not be considered as part of the AMCA Certified Rating.
marsair.com
(800)421-1266