7. After a few seconds the spa should have water
flowing from the jets. If the pump has not
primed and the water is not flowing from the jets
after two minutes TURN OFF POWER TO
THE SPA and vent air from the pumps by
slightly opening the pump unions.
8. The factory default setting for water temperature
is 102°F (39°C). Use the TEMP pad on the
control panel to set the water temperature to
the desired level. (See TEMPERATURE DISPLAY
AND ADJUSTMENT.) Your spa will heat at the
rate of approximately one degree per hour for
120V systems and five degrees per hour for
240V systems.
Start-up procedure for Quest, Destiny, Reward,
Escape, and Euphoria:
1. Place spa on a hard, flat, level surface. Make
sure the power supply is off.
2. Make sure the suction guard(s) in the footwell
are in place and undamaged.
3. Open the equipment door. For Reward, Escape,
and Euphoria, check to make sure the freeze
line between pump one and pump two is
properly connected. For Quest and Destiny,
screw the pump plug (supplied in packet) into
the face of the pump. (See EQUIPMENT DIA-
GRAM.) Close the drain valve in the equipment
bay. Screw the plug in the hose connector
located on the external DuraBase. Tighten all
disconnects and open all shut-off valves.
4. Install filter cartridges. (See INSTALLATION
INSTRUCTIONS, Filter Cartridge(s).)
5. Fill the spa with water to two-thirds of the way
up the Vortex skimmer openings. The use of a
Fill Filter is recommended, especially in areas
with high mineral content in the water.
6. Turn the power on.
7. Your spa is now in “pump priming” mode and a
“Pr” message displays in the LCD window of
the control panel. While in this mode the spa
appears idle, which lasts approximately four to
five minutes if not exited manually. To exit
manually, press the TEMP pad.
8. At this time the spa should have water flowing
from the jets. If the pump has not primed and
the water is not flowing from the jets after two
minutes TURN OFF POWER TO THE SPA and
vent air from the pumps by slightly opening the
pump unions. After turning the power on again,
the spa initiates a new priming mode. Repeat
steps above.
PAGE 16
starting your spa
Fill spa two-thirds of
the way up the Vortex
skimmer opening.
Screw pump plug into
face of pump.
Vent air by slightly
opening pump unions.
MARQUIS SPAS
Close drain valve in
equipment bay.
Screw plug in hose
connector.