Owner`s manual

A pressure wire connector is located on the exterior
of the control box. This pressure wire connector
should be bonded with at least #8 AWG (8.42mm
2
,
#6 in Canada) copper wire to any metal ladder,
metal water pipe, common bonding grid (reinforced
concrete slab, ground plate beneath the spa), or any
other metal within five feet of the spa.
120 Volt:
120V units must only be connected to a properly
grounded, grounding type 15 amp dedicated recep-
tacle. 120V equipment is designed to operate on
60Hz alternating current only at a voltage of 120,
12.5 amp. maximum load. Only use the cord pro-
vided with the spa, do not use an extension cord.
To Convert 120V to 240V:
All connections must be made by a licensed
electrician.
1. Disconnect power by unplugging from recep-
tacle and remove cord from terminal block.
2. Move both red wires TB-1 to TB-4 as indicated
by gray area.
3. Move the Heater Mode selector (J23) on the
Control Board from (20A) to (50A) position.
Ground Fault Circuit Interrupters (GFCI), #8145,
are available from your Marquis dealer.
4. Refer to 240V installation, page 13.
PAGE 14
installation instructions
120V electrical diagram
MARQUIS SPAS
Convert 120V to 240V
electrical diagram