Owner`s manual

SUCTION GUARDS
The suction guard(s) in the footwell of your spa is an
opening through which the jet pump(s) draws water.
Suction fittings are equipped with a safety guard.
Suction through the fittings can be strong. The
safety guard(s) must remain in place and undam-
aged. A fitting with a damaged guard(s) can be
dangerous, especially to small children or people
with long hair. Should any part of the body become
drawn to a fitting, turn the jet pump(s) off immedi-
ately. Long hair should be restrained in a bathing
cap, never allow it to float freely in the spa. Replace
any missing or damaged suction guard(s).
NOTE: It is normal for the flow rates of the suction
fittings to vary from strong to barely noticeable.
ELECTRICAL REQUIREMENTS
It is the responsibility of the spa owner to ensure
that all electrical connections are made in accor-
dance with all electrical codes in effect at the time
of installation.
240 Volt:
All connections must be made in accordance with
the wiring diagram found on the inside of the control
box cover. Connections must be made with copper
conductors only – do not use aluminum wiring with
this system. All conductors, circuit breakers, and/or
fuses must be sized in accordance to the total
amperage load as specified:
Permanently connected
Rated 240V, 60 Hz, 50A, three wires (#6
copper) plus ground (#8 AWG copper)
Fuse or circuit breaker size: 50 amp
This equipment is designed to operate on 60Hz
alternating current only at a voltage of 240 (+ or -).
Units to be operated at 240V must have all connec-
tions made by a qualified electrician in accordance
with all electric codes in effect at the time of installa-
tion. All 240V units require four wires (line 1, line 2,
neutral, and ground). Refer to the label at the
terminal block.
NOTE: Ensure the GFCI is properly installed. Failure
to do so may result in spa malfunction or damage
which is not warranted.
PAGE 13
installation instructions
Safety guard of
suction fitting must
remain in place.
240V electrical
diagram