Owner`s manual

1. Press TEMP+, then JETS 1, then SPA LIGHT.
2.Press TEMP+ repeatedly until “gFC” is displayed, then
press JETS 1.
3.Press TEMP+ until “gC.n” is displayed, then press
JETS 1 to clear the GFCI Status; you will see gS.A”
displayed verifying that the GFCI Status has been set to
“Armed”. The system will exit this menu in 30 seconds
if no buttons are pressed.
*When you enter the GFCI menu, it always shows you the
current status first. “gS.P” means that it’s Passed (and will
do no further automated GFCI Trip Tests), “gS.A” means
that it’s Armed (and will do an automated GFCI Trip Test in
24 hours, unless a manual GFCI Trip Test is done before
that). (“gS.t”, which you are unlikely to see unless you’ve
just initiated a Trip manually, means that it’s about to Trip
within the next dozen seconds or so.)
120 Volt
120 Volt spas shall be plugged into a properly grounded,
grounding type 15 amp receptacle on a dedicated circuit. A
dedicated circuit is a circuit with no other components that
consume power, such as lights, televisions, radios, com-
puters, or other electronic devices. These could cause your
spa to malfunction by any of the following: unusual text on
the control panel, slow heating, poor jet action, tripping
house breaker, or blown fuses. Failure to follow these
instructions could lead to premature failure of spa compo-
nents that would not be covered under the warranty. The
dedicated circuit shall meet the following specifications:
Rated 120V, 60Hz, 15A (2 wires plus ground)
Circuit breaker or fuse size: 15A
The receptacle must be at least 5 feet (1.52 m)
from the spa.
The 15 foot GFCI power cord provided with the spa
must be plugged directly into the receptacle. Do
NOT use an extension cord or any other adaptor.
Actual exposed length of cord will vary by model,
but will never be less than 12 feet.
Convert 120 Volt to 240 Volt
120 Volt spas may be converted to operate on 240V, 50A.
All connections must be made by a licensed electrician.
1. Disconnect the power by unplugging the power cord
from the receptacle, removing the cord from the
terminal block on the circuit board, and storing it with
your owner’s manual.
2.Locate the white wire connecting J11 to J32 on the
circuit board. Remove the wire and discard.
3.For 50A operation, move dip switch 10 to the OFF position.
4.Install 240V power as indicated in the 240 Volt section.
5.Rated 240V, 60Hz, 50A, three wires (#6 copper)
plus ground (#8 copper), [4 wires total].
GFCIs are available from your authorized dealer.
PAGE 15
installation instructions